A-Mode Ultrasound Bladder Volume Estimation Algorithm Based on Wavelet Energy Ratio Adaptive Denoising
Sensors · 2024
DOI: 10.3390/s24061984 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Rencheng Jin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China. Hauptthemen laut MEDLINE: Urinary Bladder, Algorithms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Fundamental Research Funds for the Central Universities, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Assessing bladder function is pivotal in urological health, with bladder volume a critical indicator. Traditional devices, hindered by high costs and cumbersome sizes, are being increasingly supplemented by portable alternatives; however, these alternatives often fall short in measurement accuracy. Addressing this gap, this study introduces a novel A-mode ultrasound-based bladder volume estimation algorithm optimized for portable devices, combining efficient, precise volume estimation with enhanced usability. Through the innovative application of a wavelet energy ratio adaptive denoising method, the algorithm significantly improves the signal-to-noise ratio, preserving critical signal details amidst device and environmental noise. Ultrasonic echoes were employed to acquire positional information on the anterior and posterior walls of the bladder at several points, with an ellipsoid fitted to these points using the least squares method for bladder volume estimation. Ultimately, a simulation experiment was conducted on an underwater porcine bladder. The experimental results indicate that the bladder volume estimation error of the algorithm is approximately 8.3%. This study offers a viable solution to enhance the accuracy and usability of portable devices for urological health monitoring, demonstrating significant potential for clinical application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China.
Förderung
- the Fundamental Research Funds for the Central Universities
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Jin, R., Huang, Q., Jiang, J., & Hu, P. (2024). A-Mode Ultrasound Bladder Volume Estimation Algorithm Based on Wavelet Energy Ratio Adaptive Denoising. Sensors. https://doi.org/10.3390/s24061984
Vancouver
Jin R, Huang Q, Jiang J, Hu P. A-Mode Ultrasound Bladder Volume Estimation Algorithm Based on Wavelet Energy Ratio Adaptive Denoising. Sensors. 2024. doi:10.3390/s24061984
BibTeX
@article{Jin2024,
author = {Jin, Rencheng and Huang, Qipeng and Jiang, Jiaxu and Hu, Peihao},
title = {A-Mode Ultrasound Bladder Volume Estimation Algorithm Based on Wavelet Energy Ratio Adaptive Denoising},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24061984}
}
EUVIMED