Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2026. Verfasst von Tyler A Bodily und 9 weiteren Autor:innen. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques, Transistors, Electronic, Graphite. Die Arbeit nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We aimed to develop a scalable, low-power graphene field-effect transistor (GFET) crossbar array integrated with a neural-interface system-on-chip (NISoC), termed the GFET-NISoC platform, for multiplexed, real-time biomolecular sensing, including ultra-sensitive detection of $\boldsymbol{Pb}^{\mathbf 2+}$ using a G-quadruplex ssDNA aptamer. A 12 $\boldsymbol{\times}$ 12 GFET crossbar array was fabricated using a multilayer dielectric stack and optimized graphene transfer. Characterization was performed using both benchtop instrumentation and a low-power NISoC front-end supporting current- and voltage-clamp modes. Ionic strength, pH, and $\boldsymbol{Pb}^{\mathbf 2+}$ dose-response measurements were obtained from functionalized arrays. The platform demonstrated uniform Dirac behavior, reversible pH-dependent conductance, predictable ionic-strength responses, and femtomolar-level $\boldsymbol{Pb}^{\mathbf 2+}$ detection with strong selectivity over $\boldsymbol{Ca}^{\mathbf 2+}$ and $\boldsymbol{Co}^{\mathbf 2+}$ . The GFET-NISoC system enables multiplexed, multi-modal sensing at sub-µW power levels and provides a promising foundation for wearable or point-of-care chemical and biomolecular monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesTransistors, ElectronicGraphiteHydrogen-Ion ConcentrationOsmolar ConcentrationG-QuadruplexesEquipment Design

Substanzen

Aptamers, NucleotideGraphite

Zitieren

APA

Bodily, T. A., Lee, M. S., Ramanathan, A., Coburn, N. J., Paul, A., Karkisaval-Ganapati, A., Xu, Y., Vazquez-Mena, O., Lal, R., & Cauwenberghs, G. (2026). Multiplexed Crossbar GFET Array With BioADC for Multimodal Aptamer-Based Sensing. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2026.3708792

Vancouver

Bodily TA, Lee MS, Ramanathan A, Coburn NJ, Paul A, Karkisaval-Ganapati A, et al. Multiplexed Crossbar GFET Array With BioADC for Multimodal Aptamer-Based Sensing. IEEE Transactions on Biomedical Circuits and Systems. 2026. doi:10.1109/tbcas.2026.3708792

BibTeX
@article{Bodily2026,
  author = {Bodily, Tyler A and Lee, Min Suk and Ramanathan, Anirudh and Coburn, Nigel J and Paul, Akshay and Karkisaval-Ganapati, Abhijith and Xu, Yuchen and Vazquez-Mena, Oscar and Lal, Ratnesh and Cauwenberghs, Gert},
  title = {Multiplexed Crossbar GFET Array With BioADC for Multimodal Aptamer-Based Sensing},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2026},
  doi = {10.1109/tbcas.2026.3708792}
}
Kostenlos starten →