Nanostructure-gated organic electrochemical transistors for accurate glucose monitoring in dynamic biological pH conditions

Ke Meng, Jia Zhu, Tianyao Zhang, Xianzhe Zhang, Yingying Zhang, Xiangjie Chen, Fan Li, Yao Tong, Senhao Zhang, Donghai Qiu, Hongbo Yang, Shangbin Liu und 9 weitere

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117677 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Ke Meng und 20 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, Glucose, Nanostructures. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 86 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, NIH, National Natural Science Foundation of China National Outstanding Youth Science Fund Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-invasive, real-time, and continuous monitoring of trace amounts of glucose in near-neutral biofluids is significant for the daily care and treatment of diabetic patients or people with suboptimal health status. Despite improved sensing performance with novel low-dimensional materials or porous structures in various enzymatic and non-enzymatic electrochemical glucose sensors, they still suffer from high cost, poor long-term stability, and performance fluctuations in varied temperature and pH. This work synergistically combines an Au-modified porous laser-induced graphene (LIG) gate electrode with an organic electrochemical transistor (OECT) to create a flexible non-enzymatic glucose sensor. The resulting OECT-based non-enzymatic glucose sensor exhibits significantly enhanced sensitivity in near-neutral biofluids, the limit of detection (LOD) (0.08 μM in pH = 7.4), excellent stability over time (degradation of ∼10 % in 180 days) and against temperature changes (30 °C-40 °C), self-pH calibration capabilities, and uncompromised sensing performance with shrinking sizes. The highly consistent laser patterning technique and in situ galvanic reduction process for electrode modifications not only provide a simple yet versatile approach to creating low-cost, compact sensing platforms for precise and real-time sweat glucose measurements but also support scalable production, allowing the correlation study of key biomarkers in sweat and blood.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrochemical TechniquesGlucoseNanostructuresBlood GlucoseHydrogen-Ion ConcentrationHumansTransistors, ElectronicGraphiteLimit of DetectionGoldEquipment DesignSweat

Stichwörter der Autor:innen

Laser-induced graphene nanocompositeLong-term stabilityNon-enzymatic glucose sensorOrganic electrochemical transistorSelf-pH calibration

Substanzen

GraphiteGlucoseGoldBlood Glucose

Autor:innen und Institutionen

  • School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China; Yangtze Delta Region Institute (Quzhou), University of Electronics Science and Technology of China, Quzho…
  • Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA.
  • Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, 215011, China.
  • School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China.
  • Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu, 610041, China.

Förderung

  • Fundamental Research Funds for the Central Universities
  • NIH
  • National Natural Science Foundation of China National Outstanding Youth Science Fund Project
  • National Natural Science Foundation of China
  • National Science Foundation
  • Pennsylvania State University
  • University of Electronic Science and Technology of China
  • NSF

Zitieren

APA

Meng, K., Zhu, J., Zhang, T., Zhang, X., Zhang, Y., Chen, X., Li, F., Tong, Y., Zhang, S., Qiu, D., Yang, H., Liu, S., Yin, L., Zhao, R., Huang, L., Li, T., Gao, M., Pan, T., Yang, J., …, & Lin, Y. (2025). Nanostructure-gated organic electrochemical transistors for accurate glucose monitoring in dynamic biological pH conditions. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117677

Vancouver

Meng K, Zhu J, Zhang T, Zhang X, Zhang Y, Chen X, et al. Nanostructure-gated organic electrochemical transistors for accurate glucose monitoring in dynamic biological pH conditions. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117677

BibTeX
@article{Meng2025,
  author = {Meng, Ke and Zhu, Jia and Zhang, Tianyao and Zhang, Xianzhe and Zhang, Yingying and Chen, Xiangjie and Li, Fan and Tong, Yao and Zhang, Senhao and Qiu, Donghai and Yang, Hongbo and Liu, Shangbin and Yin, Lan and Zhao, Rui and Huang, Libin and Li, Tao and Gao, Min and Pan, Taisong and Yang, Jian and Cheng, Huanyu and Lin, Yuan},
  title = {Nanostructure-gated organic electrochemical transistors for accurate glucose monitoring in dynamic biological pH conditions},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117677}
}
Kostenlos starten →