A flexible graphene-printed sensing platform for real-time multi-analyte detection of pH, sodium, and potassium
Biosensors and Bioelectronics · 2026-11 · 312 · 119057
DOI: 10.1016/j.bios.2026.119057 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Chengxing Lian und 8 weiteren Autor:innen. Beteiligte Einrichtung: Imperial College London, Department of Chemistry, Molecular Sciences Research Hub, 82 Wood Lane, London, W12 0BZ, UK. Hauptthemen laut MEDLINE: Biosensing Techniques, Potassium, Sodium, Graphite. Die Arbeit nennt 99 Literaturangaben. Gefördert von: Engineering and Physical Sciences Research Council, Medical Research Council, Fundação de Amparo à Pesquisa do Estado de São Paulo.
Abstract (Originalsprache)
Flexible point-of-care testing (PoCT) with simultaneous, real-time biomarker monitoring is essential for next-generation wearable health platforms. Here, we present a graphene-printed electrolyte-gated field-effect transistor (EG-GFET) sensing platform fabricated on a flexible polyimide PCB substrate for multiplexed detection of pH, sodium (Na+), and potassium (K+). Graphene ink synthesised via liquid-phase exfoliation was spray-coated to form the active transistor channel. Optimised EG-GFET sensors achieved a pH sensitivity of 25.77 ± 1.42 mV/pH (shift of Dirac point) and 61.59 ± 3.17 μA/pH (modulation of drain current). Ion-selective membranes enabled selective Na+ and K+ sensing with sensitivities of - 61.28 ± 2.95 mV/log10 [Na+] and - 56.09 ± 3.28 mV/log10 [K+], respectively, over linear concentration ranges of 50 μM - 350 mM for Na+ and 50 μM - 150 mM for K+. The flexible devices maintained stable operation under bending angles up to 120°. Real-time dual-analyte experiments further demonstrated simultaneous pH/Na+ and pH/K+ monitoring with minimal observable cross-interference. The platform was further evaluated in acidic and alkaline artificial sweat for pH, Na+, and K+ sensing. These results establish a flexible printed EG-GFET platform for pH and electrolyte sensing in buffer solutions and selected artificial-biofluid matrices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Imperial College London, Department of Chemistry, Molecular Sciences Research Hub, 82 Wood Lane, London, W12 0BZ, UK.
- Imperial College London, Department of Chemistry, Molecular Sciences Research Hub, 82 Wood Lane, London, W12 0BZ, UK; São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, 13560-970, Brazil.
- São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, 13560-970, Brazil.
- Imperial College London, Department of Chemistry, Molecular Sciences Research Hub, 82 Wood Lane, London, W12 0BZ, UK; Dipartimento di Fisica e Astronomia, Università di Catania & CNR-IMM (Catania Università), Via S. Sof…
Förderung
- Engineering and Physical Sciences Research Council
- Medical Research Council
- Fundação de Amparo à Pesquisa do Estado de São Paulo
- Imperial College London
- China Scholarship Council
Zitieren
APA
Lian, C., Li, M., Fenech-Salerno, B., Martins, T. S., Wu, S., Holicky, M., Oliveira, O. N., Cass, A. E. G., & Torrisi, F. (2026). A flexible graphene-printed sensing platform for real-time multi-analyte detection of pH, sodium, and potassium. Biosensors and Bioelectronics, 312, 119057. https://doi.org/10.1016/j.bios.2026.119057
Vancouver
Lian C, Li M, Fenech-Salerno B, Martins TS, Wu S, Holicky M, et al. A flexible graphene-printed sensing platform for real-time multi-analyte detection of pH, sodium, and potassium. Biosensors and Bioelectronics. 2026;312:119057. doi:10.1016/j.bios.2026.119057
BibTeX
@article{Lian2026,
author = {Lian, Chengxing and Li, Mingyuan and Fenech-Salerno, Benji and Martins, Thiago Serafim and Wu, Shuwei and Holicky, Martin and Oliveira, Osvaldo N and Cass, Anthony E G and Torrisi, Felice},
title = {A flexible graphene-printed sensing platform for real-time multi-analyte detection of pH, sodium, and potassium},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {312},
pages = {119057},
doi = {10.1016/j.bios.2026.119057}
}
EUVIMED