EUVIMEDEUVIMED entdecken
Crossref

Self-Adaptive Pseudo-Resistors Enabling Millisecond-Level Artifact Recovery and High-Linearity for Neural Recording Front-Ends

Hui Wu, Ziqi Tan, Xing Liu, Jinbo Chen, Wenjun Zou, Qiming Hou, Siyu Lin, Yutao Mao, Xiaofei Kuang, Jie Yang, Mohamad Sawan

IEEE Transactions on Biomedical Circuits and Systems · 2026

DOI: 10.1109/tbcas.2025.3644885 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2026. Verfasst von Hui Wu und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Neurons. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Westlake University, and in part by the “Pioneer” and “Leading Goose” R&D Program of Zhejiang.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The therapeutic efficacy of closed-loop neuromodulation is critically undermined by stimulation artifacts that create a prolonged amplifier blind period', obscuring neural biomarkers. While state-of-the-art solutions mitigate this by adding complexity around the amplifier-such as active reset, blanking, or digital cancellation-they introduce trade-offs like data loss or computational overhead. In a distinct departure from these approaches, this paper solves the problem at its root by introducing a state-aware feedback element: a self-adaptive pseudo-resistor (A-PR). The A-PR architecture integrates two key innovations: an adaptive Floating Power Supply (FPS) that senses DC errors and autonomously collapses the feedback resistance for rapid recovery, and a process-insensitive Self-Biased Current Source (SBCS) that ensures robust, uniform performance against PVT variations. A complete neural recording front-end featuring the A-PR was fabricated in a 40-nm CMOS process. Measurement results validate the core claims, demonstrating a sub-3-ms recovery time from a 1-V artifact, an input-referred noise of 5.23 µVrms, and a tunable high-pass corner, all while consuming only 2.3 µW and occupying 0.015 mm2. By eliminating the trade-off between fast recovery and high fidelity, the A-PR provides a scalable, low-power solution for next-generation, high-resolution closed-loop neural interfaces.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeuronsArtifactsEquipment DesignHumansAmplifiers, ElectronicSignal Processing, Computer-Assisted

Förderung

  • Westlake University, and in part by the “Pioneer” and “Leading Goose” R&D Program of Zhejiang

Zitieren

APA

Wu, H., Tan, Z., Liu, X., Chen, J., Zou, W., Hou, Q., Lin, S., Mao, Y., Kuang, X., Yang, J., & Sawan, M. (2026). Self-Adaptive Pseudo-Resistors Enabling Millisecond-Level Artifact Recovery and High-Linearity for Neural Recording Front-Ends. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2025.3644885

Vancouver

Wu H, Tan Z, Liu X, Chen J, Zou W, Hou Q, et al. Self-Adaptive Pseudo-Resistors Enabling Millisecond-Level Artifact Recovery and High-Linearity for Neural Recording Front-Ends. IEEE Transactions on Biomedical Circuits and Systems. 2026. doi:10.1109/tbcas.2025.3644885

BibTeX
@article{Wu2026,
  author = {Wu, Hui and Tan, Ziqi and Liu, Xing and Chen, Jinbo and Zou, Wenjun and Hou, Qiming and Lin, Siyu and Mao, Yutao and Kuang, Xiaofei and Yang, Jie and Sawan, Mohamad},
  title = {Self-Adaptive Pseudo-Resistors Enabling Millisecond-Level Artifact Recovery and High-Linearity for Neural Recording Front-Ends},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2026},
  doi = {10.1109/tbcas.2025.3644885}
}
Kostenlos starten →