EUVIMEDEUVIMED entdecken
Crossref

A Voltage-Assist 16-Channel Electrochemical Biosensor With Linearity Compensation

Yifei Fan, Dongmin Shi, Yanhang Chen, Qifeng Huang, Siji Huang, Qiwei Zhao, Saqib Mohamad, Jie Yuan

IEEE Transactions on Biomedical Circuits and Systems · 2025

DOI: 10.1109/tbcas.2024.3401784 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2025. Verfasst von Yifei Fan und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques. Die Arbeit nennt 43 Literaturangaben. Gefördert von: The Hong Kong Government Innovation and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Large capacitive loading of electrodes induces massive error current and imperfect settling in the electrochemical signal acquisition process, leading to inaccurate acquisition results. To efficiently mitigate this inaccuracy, this paper presents a current-and-voltage dual-mode acquisition technique in which a voltage front-end (VFE) is employed to acquire the electrode voltage error and compensate the nonlinearity induced by the electrode capacitive loading. Therefore, the gain and bandwidth requirements of the current front end (CFE) can be relaxed to reduce the complexity and power consumption. With a relieved gain requirement, an inverter-based capacitive trans-impedance amplifier (IB-CTIA) is adopted to boost the input transconductance for low-noise design. By reusing the supply current, the IB-CTIA effectively achieves a low input-referred current noise of 3.9 pArms and a dynamic range (DR) of 126 dB with only 18-μW static power. The prototype chip is fabricated in a 180-nm CMOS process. Interleukin-6 immunoassays (IL-6) are implemented to verify the chip's performance. With the proposed nonlinear error compensation, the correlation coefficient of the detection result is improved from 0.951 to 0.980 and the limit of detection (LoD) is reduced from 8.31 pg/mL to 6.90 pg/mL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrochemical TechniquesEquipment DesignElectrodesInterleukin-6Amplifiers, ElectronicImmunoassayElectric CapacitanceHumans

Substanzen

Interleukin-6

Förderung

  • The Hong Kong Government Innovation and Technology

Zitieren

APA

Fan, Y., Shi, D., Chen, Y., Huang, Q., Huang, S., Zhao, Q., Mohamad, S., & Yuan, J. (2025). A Voltage-Assist 16-Channel Electrochemical Biosensor With Linearity Compensation. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2024.3401784

Vancouver

Fan Y, Shi D, Chen Y, Huang Q, Huang S, Zhao Q, et al. A Voltage-Assist 16-Channel Electrochemical Biosensor With Linearity Compensation. IEEE Transactions on Biomedical Circuits and Systems. 2025. doi:10.1109/tbcas.2024.3401784

BibTeX
@article{Fan2025,
  author = {Fan, Yifei and Shi, Dongmin and Chen, Yanhang and Huang, Qifeng and Huang, Siji and Zhao, Qiwei and Mohamad, Saqib and Yuan, Jie},
  title = {A Voltage-Assist 16-Channel Electrochemical Biosensor With Linearity Compensation},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2025},
  doi = {10.1109/tbcas.2024.3401784}
}
Kostenlos starten →