EUVIMEDEUVIMED entdecken
Crossref

An Ultra-Low-Power Amplifier-Less Potentiostat Design Based on Digital Regulation Loop

Muhammad Abrar Akram, Aida Aberra, Soon-Jae Kweon, Sohmyung Ha

IEEE Transactions on Biomedical Circuits and Systems · 2025

DOI: 10.1109/tbcas.2025.3527652 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2025. Verfasst von Muhammad Abrar Akram und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Biosensing Techniques, Amplifiers, Electronic, Electrochemical Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Research Foundation of Korea (NRF) through the Korea government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a new potentiostat circuit architecture for interfaces with amperometric electrochemical biosensors. The proposed architecture, which is based on a digital low-dropout regulator (DLDO) structure, successfully eliminates the need for transimpedance amplifier (TIA), control amplifier, and other passive elements unlike other typical potentiostat topologies. It can regulate the required electrode voltages and measure the sensor currents ($\textit{I}_{\textit{SENSE}}$) at the same time by using a simple implementation with clocked comparators, digital loop filters, and current-steering DACs. Three different configurations of the proposed potentiostat are discussed including single-side regulated (SSR) potentiostat, dual-side regulated (DSR) potentiostat, and differential sensing DSR potentiostat with a background working electrode. These proposed potentiostats were designed and fabricated in a 180 nm complementary metal-oxide semiconductor (CMOS) process, occupying an active silicon areas of 0.0645 mm${}^{2}$, 0.1653 mm${}^{2}$, and 0.266 mm${}^{2}$, respectively. Validation results demonstrate that the proposed potentiostats operate on a wide sampling frequency range from 100 Hz to 100 MHz and supply voltage range from 1 V to 1.8 V. The proposed DSR potentiostat achieves a minimal power consumption of 3.7 nW over the entire dynamic range of 129.5 dB.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAmplifiers, ElectronicElectrochemical TechniquesEquipment DesignSemiconductorsElectrodes

Förderung

  • National Research Foundation of Korea (NRF) through the Korea government

Zitieren

APA

Akram, M. A., Aberra, A., Kweon, S. J., & Ha, S. (2025). An Ultra-Low-Power Amplifier-Less Potentiostat Design Based on Digital Regulation Loop. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2025.3527652

Vancouver

Akram MA, Aberra A, Kweon SJ, Ha S. An Ultra-Low-Power Amplifier-Less Potentiostat Design Based on Digital Regulation Loop. IEEE Transactions on Biomedical Circuits and Systems. 2025. doi:10.1109/tbcas.2025.3527652

BibTeX
@article{Akram2025,
  author = {Akram, Muhammad Abrar and Aberra, Aida and Kweon, Soon-Jae and Ha, Sohmyung},
  title = {An Ultra-Low-Power Amplifier-Less Potentiostat Design Based on Digital Regulation Loop},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2025},
  doi = {10.1109/tbcas.2025.3527652}
}
Kostenlos starten →