EUVIMEDEUVIMED entdecken
Crossref

Nitrocellulose/acrylic resin coated screen-printed carbon electrode to construct a capacitive immunosensor for anti-BSA

Pei-Chia Tsai, Richie L C Chen, Bo-Chuan Hsieh, Tzong-Jih Cheng

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116376 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Pei-Chia Tsai und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrodes, Carbon, Acrylic Resins. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Ministry of Science and Technology, Taiwan, Ministry of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The capacitive immunosensor, known for its label-free simplicity, has great potential for point-of-care diagnostics. However, the interaction between insulation and recognition layers on the sensing electrode greatly affects its performance. This study introduces a pioneering dual-layer strategy, implementing a novel combination of acrylic resin (AR) and nitrocellulose (NC) coatings on screen-printed carbon electrodes (SPCEs). This innovative approach not only enhances the dielectric properties of the capacitive sensor but also streamlines the immobilization of recognizing elements. Particularly noteworthy is the superior reliability and insulation offered by the AR coating, surpassing the limitations of traditional self-assembled monolayer (SAM) modifications. This dual-layer methodology establishes a robust foundation for constructing capacitive sensors optimized specifically for liquid medium-based biosensing applications. The NC coating in this study represents a breakthrough in effectively immobilizing BSA, unraveling the capacitive response intricately linked to the quantity of adsorbed recognizing elements. The results underscore the prowess of the proposed immunosensor, showcasing a meticulously defined linear calibration curve for anti-BSA (ranging from 0 to 25 μg/ml). Additionally, specific interactions with anti-HAS and anti-TNF-α further validate the versatility and efficacy of the developed immunosensor. This work presents a streamlined and highly efficient protocol for developing label-free immunosensors for antibody determination and introduces a paradigm shift by utilizing readily available electrodes and sensing systems. The findings are poised to catalyze a significant acceleration in the advancement of biosensor technology, opening new avenues for innovative applications in point-of-care diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrodesCarbonAcrylic ResinsCollodionSerum Albumin, BovineImmunoassayHumansElectric CapacitanceLimit of DetectionElectrochemical TechniquesAntibodies, ImmobilizedAnimals

Stichwörter der Autor:innen

Acrylic resinAnti-BSACapacitiveInmmunosensorNitrocelluloseScreen-printed carbon electrode

Substanzen

CarbonAcrylic ResinsCollodionSerum Albumin, BovineAntibodies, Immobilized

Autor:innen und Institutionen

  • Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan.
  • Department of Biomechatronics Engineering, College of Bio-Resources and Agriculture, National Taiwan University, Taipei, Taiwan. Electronic address: tzongjih@ntu.edu.tw.

Förderung

  • Ministry of Science and Technology, Taiwan
  • Ministry of Science and Technology

Zitieren

APA

Tsai, P. C., Chen, R. L. C., Hsieh, B. C., & Cheng, T. J. (2024). Nitrocellulose/acrylic resin coated screen-printed carbon electrode to construct a capacitive immunosensor for anti-BSA. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116376

Vancouver

Tsai PC, Chen RLC, Hsieh BC, Cheng TJ. Nitrocellulose/acrylic resin coated screen-printed carbon electrode to construct a capacitive immunosensor for anti-BSA. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116376

BibTeX
@article{Tsai2024,
  author = {Tsai, Pei-Chia and Chen, Richie L C and Hsieh, Bo-Chuan and Cheng, Tzong-Jih},
  title = {Nitrocellulose/acrylic resin coated screen-printed carbon electrode to construct a capacitive immunosensor for anti-BSA},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116376}
}
Kostenlos starten →