A 2.3–5.7 μ W Tri-Modal Self-Adaptive Photoplethysmography Sensor Interface IC for Heart Rate, SpO 2 , and Pulse Transit Time Co-Monitoring
IEEE Transactions on Biomedical Circuits and Systems · 2024
DOI: 10.1109/tbcas.2024.3360140 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024. Verfasst von Peng Wang und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Photoplethysmography, Heart Rate, Signal Processing, Computer-Assisted, Pulse Wave Analysis. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: National Science Foundation, Nanosystems Engineering Research Center, Advanced Self-Powered Systems of Integrated Sensors and Technologies.
Abstract (Originalsprache)
This paper presents a tri-modal self-adaptive photoplethysmography (PPG) sensor interface IC for concurrently monitoring heart rate, SpO2, and pulse transit time, which is a critical intermediate parameter to derive blood pressure. By implementing a highly-reconfigurable analog front-end (AFE) architecture, flexible signal chain timing control, and flexible dual-LED drivers, this sensor interface provides wide operating space to support various PPG-sensing use cases. A heart-beat-locked-loop (HBLL) scheme is further extended to achieve time-multiplexed dual-input pulse transit time extraction based on two PPG sensors placed at fingertip and chest. A self-adaptive calibration scheme is proposed to automatically match the chip's operating point with the current use case, guaranteeing a sufficient signal-to-noise ratio for the user while consuming minimum system power. This paper proposes a DC offset cancellation (DCOC) approach comprised by a logarithmic transimpedance amplifier and an 8-bit SAR ADC, achieving a measured 38 nA residue error and 8.84 μA maximum input current. Fabricated in a 65nm CMOS process, the proposed tri-modal PPG sensor interface consumes 2.3-5.7 μW AFE power and 1.52 mm2 die area with 102dB (SpO2 mode), 110-116 dB (HR & PTT mode) dynamic range. A SpO2 test case and a HR & PTT test case are both demonstrated in the paper, achieving 18.9 μW and 43.7 μW system power, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- National Science Foundation
- Nanosystems Engineering Research Center
- Advanced Self-Powered Systems of Integrated Sensors and Technologies
- NSF Graduate Research Fellowship
Zitieren
APA
Wang, P., Agarwala, R., Ownby, N. B., Liu, X., & Calhoun, B. H. (2024). A 2.3–5.7 μ W Tri-Modal Self-Adaptive Photoplethysmography Sensor Interface IC for Heart Rate, SpO 2 , and Pulse Transit Time Co-Monitoring. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2024.3360140
Vancouver
Wang P, Agarwala R, Ownby NB, Liu X, Calhoun BH. A 2.3–5.7 μ W Tri-Modal Self-Adaptive Photoplethysmography Sensor Interface IC for Heart Rate, SpO 2 , and Pulse Transit Time Co-Monitoring. IEEE Transactions on Biomedical Circuits and Systems. 2024. doi:10.1109/tbcas.2024.3360140
BibTeX
@article{Wang2024,
author = {Wang, Peng and Agarwala, Rishika and Ownby, Natalie B and Liu, Xinjian and Calhoun, Benton H},
title = {A 2.3–5.7 μ W Tri-Modal Self-Adaptive Photoplethysmography Sensor Interface IC for Heart Rate, SpO 2 , and Pulse Transit Time Co-Monitoring},
journal = {IEEE Transactions on Biomedical Circuits and Systems},
year = {2024},
doi = {10.1109/tbcas.2024.3360140}
}
EUVIMED