A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring
Sensors · 2024
DOI: 10.3390/s24237634 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Farjana Akter Jhuma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Major of Device Science and Engineering, Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka 8160811, Japan. Hauptthemen laut MEDLINE: Photoplethysmography, Heart Rate, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A photoplethysmography (PPG) sensor is a cost-effective and efficacious way of measuring health conditions such as heart rate, oxygen saturation, and respiration rate. In this work, we present a hybrid PPG sensor system working in a reflective mode with an optoelectronic module, i.e., the combination of an inorganic light-emitting diode (LED) and a circular-shaped organic photodetector (OPD) surrounding the LED for efficient light harvest followed by the proper driving circuit for accurate PPG signal acquisition. The performance of the hybrid sensor system was confirmed by the heart rate detection process from the PPG using fast Fourier transform analysis. The PPG signal obtained with a 50% LED duty cycle and 250 Hz sampling rate resulted in accurate heart rate monitoring with an acceptable range of error. The effects of the LED duty cycle and the LED luminous intensity were found to be crucial to the heart rate accuracy and to the power consumption, i.e., indispensable factors for the hybrid sensor.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Major of Device Science and Engineering, Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka 8160811, Japan.
- OPERA Solutions Inc., 5-5 Kyudai-Shimmachi, Nishi-ku, Fukuoka 8190388, Japan.
ORCID-Profile: Farjana Akter Jhuma, Kentaro Harada, Muhamad Affiq Bin Misran
Zitieren
APA
Jhuma, F. A., Harada, K., Misran, M. A. B., Mo, H. W., Fujimoto, H., & Hattori, R. (2024). A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring. Sensors. https://doi.org/10.3390/s24237634
Vancouver
Jhuma FA, Harada K, Misran MAB, Mo HW, Fujimoto H, Hattori R. A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring. Sensors. 2024. doi:10.3390/s24237634
BibTeX
@article{Jhuma2024,
author = {Jhuma, Farjana Akter and Harada, Kentaro and Misran, Muhamad Affiq Bin and Mo, Hin-Wai and Fujimoto, Hiroshi and Hattori, Reiji},
title = {A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24237634}
}