EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Preliminary Demonstration of Pulse-Echo Imaging With a Long Monolithic Flexible CMUT Array

Amirhossein Omidvar, Robert N. Rohling, Edmond Cretu, Mark E. Cresswell, Antony J. Hodgson

IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control · 2024 · 4 · 191-203

DOI: 10.1109/ojuffc.2024.3506532 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Amirhossein Omidvar und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Canadian Natural Sciences and Engineering Research Council, Canadian Institutes of Health Research, Government of Canada’s New Frontiers in Research Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conformal ultrasound imaging using large-area transducer arrays is an emerging technology with significant potential for real-time, continuous, functional, and health monitoring applications. This study addresses the challenge of fabricating such transducer arrays by presenting the development and preliminary imaging performance of a monolithic flexible capacitive micromachined ultrasonic transducer (CMUT) array—the longest reported to date. A 128-element, 91 mm long flexible array was designed and fabricated using a lithography process, with SU-8 CMUT structures on a bendable polyimide substrate. The array was then packaged by mounting it onto a flexible printed circuit board and coated with a thin polydimethylsiloxane (PDMS) layer for in vivo testing. Electrical impedance measurements confirmed the full functionality of all transducer elements, with an average center resonant frequency of 5.84 MHz (SD: 0.14 MHz). Pulse-echo imaging experiments demonstrated the array’s capability to detect specular reflections and resolve fine features under various curvatures. In vivo scans revealed outlines of a finger and superficial tissues in the forearm. Despite the limitations associated with the lack of custom front-end electronics and low signal-to-noise ratio beamforming strategies, this work demonstrates the feasibility of manufacturing a flexible CMUT array suitable for large-area conformal sonography.

Förderung

  • Canadian Natural Sciences and Engineering Research Council
  • Canadian Institutes of Health Research
  • Government of Canada’s New Frontiers in Research Fund

Zitieren

APA

Omidvar, A., Rohling, R. N., Cretu, E., Cresswell, M. E., & Hodgson, A. J. (2024). Preliminary Demonstration of Pulse-Echo Imaging With a Long Monolithic Flexible CMUT Array. IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, 4, 191-203. https://doi.org/10.1109/ojuffc.2024.3506532

Vancouver

Omidvar A, Rohling RN, Cretu E, Cresswell ME, Hodgson AJ. Preliminary Demonstration of Pulse-Echo Imaging With a Long Monolithic Flexible CMUT Array. IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control. 2024;4:191-203. doi:10.1109/ojuffc.2024.3506532

BibTeX
@article{Omidvar2024,
  author = {Omidvar, Amirhossein and Rohling, Robert N. and Cretu, Edmond and Cresswell, Mark E. and Hodgson, Antony J.},
  title = {Preliminary Demonstration of Pulse-Echo Imaging With a Long Monolithic Flexible CMUT Array},
  journal = {IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2024},
  volume = {4},
  pages = {191--203},
  doi = {10.1109/ojuffc.2024.3506532}
}
Kostenlos starten →