Circular Polarimetric Imaging with a Metamaterial Integrated Long‐Wavelength Infrared Focal Plane Array
Advanced Science · 2025-10 · 12 (39)
DOI: 10.1002/advs.202509292 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 25.07.2025. Verfasst von Tianyun Zhu und 11 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yu Tian Road, Shanghai, 200083, C…. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Strategic Priority Research Program of the Chinese Academy of Sciences, National Key Research and Development Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Long‐wavelength infrared (LWIR) circular polarimetric imaging plays an important role in many areas. The immediacy of polarimetric imaging and the miniaturization of devices drive considerable efforts to division‐of‐focal‐plane‐array (DoFPA) circular polarimeters. However, the realization of such detectors is hampered by low polarization discrimination, reduced absorption in the detection material, and fabrication complexity. The situation becomes more serious in the LWIR range since the pixel size is only a few wavelengths of the incident light. Here, a quantum well infrared photodetector based LWIR DoFPA circular polarimeter featuring a 320 × 256 pixel array integrated with a chiral meta‐mirror array is established. The spectral range of this detector is from 10 to 11 µm. Taking advantage of the dual polarization selection, a CPER of 23.3 is achieved for the pixels integrated with the same chiral meta‐mirror structure, and a CPER of 5.67 for the pixels integrated with left‐ and right‐handed chiral meta‐mirror structures in a checkerboard pattern. The peak responsivity is improved by a factor of 9.13 compared to a standard reference device. With the LWIR DoFPA circular polarimeter, Stokes parameter S 3 imaging is achieved with a noise equivalent S 3 difference of 1.16×10 −4 , and demonstrate background suppression and target highlighting.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yu Tian Road, Shanghai, 200083, China.
- University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing, 100049, China.
ORCID-Profile: Xiaoshuang Chen
Förderung
- Strategic Priority Research Program of the Chinese Academy of Sciences
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Program of Shanghai Academic/Technology Research Leader
- Fund of SITP Innovation Foundation
- Special project to seize the commanding heights of science and technology of Chinese Academy of Sciences, subtopic
- Program of Shanghai Academic Research Leader
Zitieren
APA
Zhu, T., Wang, L., Jing, W., Deng, J., Ye, J., Zhang, Y., Chu, Z., Zhou, J., Chen, X., Li, X., Lu, W., & Shen, X. (2025). Circular Polarimetric Imaging with a Metamaterial Integrated Long‐Wavelength Infrared Focal Plane Array. Advanced Science, 12(39). https://doi.org/10.1002/advs.202509292
Vancouver
Zhu T, Wang L, Jing W, Deng J, Ye J, Zhang Y, et al. Circular Polarimetric Imaging with a Metamaterial Integrated Long‐Wavelength Infrared Focal Plane Array. Advanced Science. 2025;12(39). doi:10.1002/advs.202509292
BibTeX
@article{Zhu2025,
author = {Zhu, Tianyun and Wang, Ling and Jing, Wenji and Deng, Jie and Ye, Jiexian and Zhang, Yujie and Chu, Zeshi and Zhou, Jing and Chen, Xiaoshuang and Li, Xiangyang and Lu, Wei and Shen, Xuechu},
title = {Circular Polarimetric Imaging with a Metamaterial Integrated Long‐Wavelength Infrared Focal Plane Array},
journal = {Advanced Science},
year = {2025},
volume = {12},
number = {39},
doi = {10.1002/advs.202509292}
}
EUVIMED