Ultrasound Imaging with Flexible Array Transducer for Pancreatic Cancer Radiation Therapy
Cancers · 22.06.2023 · 15 (13) · 3294
DOI: 10.3390/cancers15133294 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cancers, online erschienen am 22.06.2023. Verfasst von Xinyue Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute of Health, National Cancer Institute of the National Institutes of Health.
Abstract (Originalsprache)
Pancreatic cancer with less than 10% 3-year survival rate is one of deadliest cancer types and greatly benefits from enhanced radiotherapy. Organ motion monitoring helps spare the normal tissue from high radiation and, in turn, enables the dose escalation to the target that has been shown to improve the effectiveness of RT by doubling and tripling post-RT survival rate. The flexible array transducer is a novel and promising solution to address the limitation of conventional US probes. We proposed a novel shape estimation for flexible array transducer using two sequential algorithms: (i) an optical tracking-based system that uses the optical markers coordinates attached to the probe at specific positions to estimate the array shape in real-time and (ii) a fully automatic shape optimization algorithm that automatically searches for the optimal array shape that results in the highest quality reconstructed image. We conducted phantom and in vivo experiments to evaluate the estimated array shapes and the accuracy of reconstructed US images. The proposed method reconstructed US images with low full-width-at-half-maximum (FWHM) of the point scatters, correct aspect ratio of the cyst, and high-matching score with the ground truth. Our results demonstrated that the proposed methods reconstruct high-quality ultrasound images with significantly less defocusing and distortion compared with those without any correction. Specifically, the automatic optimization method reduced the array shape estimation error to less than half-wavelength of transmitted wave, resulting in a high-quality reconstructed image.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA.
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD 21287, USA.
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21287, USA.
ORCID-Profile: Xinyue Huang, Debarghya China, Ziwei Feng, Muyinatu A Lediju Bell, Kai Ding
Förderung
- National Institute of Health
- National Cancer Institute of the National Institutes of Health
Zitieren
APA
Huang, X., Hooshangnejad, H., China, D., Feng, Z., Lee, J., Bell, M. A. L., & Ding, K. (2023). Ultrasound Imaging with Flexible Array Transducer for Pancreatic Cancer Radiation Therapy. Cancers, 15(13), 3294. https://doi.org/10.3390/cancers15133294
Vancouver
Huang X, Hooshangnejad H, China D, Feng Z, Lee J, Bell MAL, et al. Ultrasound Imaging with Flexible Array Transducer for Pancreatic Cancer Radiation Therapy. Cancers. 2023;15(13):3294. doi:10.3390/cancers15133294
BibTeX
@article{Huang2023,
author = {Huang, Xinyue and Hooshangnejad, Hamed and China, Debarghya and Feng, Ziwei and Lee, Junghoon and Bell, Muyinatu A Lediju and Ding, Kai},
title = {Ultrasound Imaging with Flexible Array Transducer for Pancreatic Cancer Radiation Therapy},
journal = {Cancers},
year = {2023},
volume = {15},
number = {13},
pages = {3294},
doi = {10.3390/cancers15133294}
}
EUVIMED