Evaluation of a Wrist-Worn Device for ECG-Based Detection of Acute Myocardial Infarction
IEEE Journal of Translational Engineering in Health and Medicine · 2026
DOI: 10.1109/jtehm.2026.3730465 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Journal of Translational Engineering in Health and Medicine, 2026. Verfasst von Karolina Eitminaviciene und 10 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering InstituteKaunas University of Technology Kaunas 44249 Lithuania. Hauptthemen laut MEDLINE: Myocardial Infarction, Electrocardiography, Wearable Electronic Devices, Signal Processing, Computer-Assisted. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Research Council of Lithuania.
Abstract (Originalsprache)
OBJECTIVE: To determine whether a two-lead ECG (wECG), acquired using a self-applicable, wrist-worn device, provides diagnostic value in acute myocardial infarction (AMI) detection. METHODS: Seventy-one patients with AMI, 26 with other cardiovascular diseases (CVDs), and 54 healthy controls were enrolled in the study. To acquire lead I, one electrode of the wrist-worn device was touched with the index finger of the opposite hand, while another lead was acquired by touching the electrode on the strap to a specific part of the body. The diagnostic value of the wECG is evaluated either directly or through synthesis of the standard 12-lead ECG using an echo state network. RESULTS: Using the standard ECG, an AMI detector based on a convolutional neural network yields a sensitivity of 0.86 and a specificity of 0.71; the corresponding figures for blinded cardiologist diagnosis are 0.77/0.88. Using the synthesized ECG, the V3 electrode touch site yields the best performance, with a sensitivity/specificity of 0.84/0.71 for AMI detection and 0.67/0.86 for cardiologist diagnosis. Compared to the synthesized ECG across all touch sites, use of the wECG results in a substantially lower sensitivity, reduced by 0.12-0.13, while the specificity is comparable or slightly higher. Implementation of a two-stage approach, consisting of detector-based screening followed by cardiologist review of positive cases, results in correct decisions in 63% of the AMI cases using either the synthesized ECG or the wECG. CONCLUSION: The two-lead ECG acquired with a wrist-worn device offers diagnostic value and enables screening for AMI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering InstituteKaunas University of Technology Kaunas 44249 Lithuania.
- Institute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.
- Center of Cardiology and AngiologyVilnius University Hospital Santaros Klinikos Vilnius 08406 Lithuania.
- Department of Biomedical EngineeringLund University Lund 221 00 Sweden.
- Department of Electronics EngineeringKaunas University of Technology Kaunas 44249 Lithuania.
ORCID-Profile: Karolina Eitminaviciene, Daivaras Sokas, Zygimantas Abramikas, Vytautas Juknevicius, Leif Sornmo, Andrius Petrenas
Förderung
- Research Council of Lithuania
Zitieren
APA
Eitminaviciene, K., Sokas, D., Abramikas, Z., Kersnauskaite, D., Sirviene, D., Sirvys, A., Stankeviciute, G., Juknevicius, V., Bacevicius, J., Sornmo, L., & Petrenas, A. (2026). Evaluation of a Wrist-Worn Device for ECG-Based Detection of Acute Myocardial Infarction. IEEE Journal of Translational Engineering in Health and Medicine. https://doi.org/10.1109/jtehm.2026.3730465
Vancouver
Eitminaviciene K, Sokas D, Abramikas Z, Kersnauskaite D, Sirviene D, Sirvys A, et al. Evaluation of a Wrist-Worn Device for ECG-Based Detection of Acute Myocardial Infarction. IEEE Journal of Translational Engineering in Health and Medicine. 2026. doi:10.1109/jtehm.2026.3730465
BibTeX
@article{Eitminaviciene2026,
author = {Eitminaviciene, Karolina and Sokas, Daivaras and Abramikas, Zygimantas and Kersnauskaite, Dziugile and Sirviene, Dominika and Sirvys, Artiomas and Stankeviciute, Guoste and Juknevicius, Vytautas and Bacevicius, Justinas and Sornmo, Leif and Petrenas, Andrius},
title = {Evaluation of a Wrist-Worn Device for ECG-Based Detection of Acute Myocardial Infarction},
journal = {IEEE Journal of Translational Engineering in Health and Medicine},
year = {2026},
doi = {10.1109/jtehm.2026.3730465}
}
EUVIMED