Screening for Major Depressive Disorder Using a Wearable Ultra-Short-Term HRV Monitor and Signal Quality Indices
Sensors · 2023
DOI: 10.3390/s23083867 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Shohei Sato und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Computer Science, Faculty of Systems Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan. Hauptthemen laut MEDLINE: Major Depressive Disorder, Wearable Electronic Devices. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, JSPS KAKENHI.
Abstract (Originalsprache)
To encourage potential major depressive disorder (MDD) patients to attend diagnostic sessions, we developed a novel MDD screening system based on sleep-induced autonomic nervous responses. The proposed method only requires a wristwatch device to be worn for 24 h. We evaluated heart rate variability (HRV) via wrist photoplethysmography (PPG). However, previous studies have indicated that HRV measurements obtained using wearable devices are susceptible to motion artifacts. We propose a novel method to improve screening accuracy by removing unreliable HRV data (identified on the basis of signal quality indices (SQIs) obtained by PPG sensors). The proposed algorithm enables real-time calculation of signal quality indices in the frequency domain (SQI-FD). A clinical study conducted at Maynds Tower Mental Clinic enrolled 40 MDD patients (mean age, 37.5 ± 8.8 years) diagnosed on the basis of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition, and 29 healthy volunteers (mean age, 31.9 ± 13.0 years). Acceleration data were used to identify sleep states, and a linear classification model was trained and tested using HRV and pulse rate data. Ten-fold cross-validation showed a sensitivity of 87.3% (80.3% without SQI-FD data) and specificity of 84.0% (73.3% without SQI-FD data). Thus, SQI-FD drastically improved sensitivity and specificity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering and Computer Science, Faculty of Systems Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan.
- Maynds Tower Mental Clinic, Tokyo 151-0053, Japan.
- Department of Psychiatry, Shizuoka Saiseikai General Hospital, Shizuoka 422-8527, Japan.
- Research Division, Saiseikai Research Institute of Health Care and Welfare, Tokyo 108-0073, Japan.
- Department of Electrical Engineering and Computer Science, Graduate School of System Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan.
Förderung
- Japan Society for the Promotion of Science
- JSPS KAKENHI
Zitieren
APA
Sato, S., Hiratsuka, T., Hasegawa, K., Watanabe, K., Obara, Y., Kariya, N., Shinba, T., & Matsui, T. (2023). Screening for Major Depressive Disorder Using a Wearable Ultra-Short-Term HRV Monitor and Signal Quality Indices. Sensors. https://doi.org/10.3390/s23083867
Vancouver
Sato S, Hiratsuka T, Hasegawa K, Watanabe K, Obara Y, Kariya N, et al. Screening for Major Depressive Disorder Using a Wearable Ultra-Short-Term HRV Monitor and Signal Quality Indices. Sensors. 2023. doi:10.3390/s23083867
BibTeX
@article{Sato2023,
author = {Sato, Shohei and Hiratsuka, Takuma and Hasegawa, Kenya and Watanabe, Keisuke and Obara, Yusuke and Kariya, Nobutoshi and Shinba, Toshikazu and Matsui, Takemi},
title = {Screening for Major Depressive Disorder Using a Wearable Ultra-Short-Term HRV Monitor and Signal Quality Indices},