EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biostrap Kairos Wristband Versus Electrocardiography for Resting Heart Rate Variability Assessment

Andrew A Flatt iD, Ann Claire E Blalock iD, Allison N Wade, Bryan L Riemann iD

Sensors · 2025

DOI: 10.3390/s25103165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Andrew A Flatt und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biodynamics and Human Performance Center, Department of Health Sciences and Kinesiology, Georgia Southern University, Armstrong Campus, 11935 Abercor…. Hauptthemen laut MEDLINE: Heart Rate, Electrocardiography, Wearable Electronic Devices. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biostrap USA LLC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Kairos wristband offers on-demand heart rate variability (HRV) assessment through its “Spot Check” feature, enabling standardized recordings for clinical, research, or self-tracking purposes, but its validity is untested. Therefore, we compared the Kairos wristband to electrocardiography (ECG) for resting HRV assessment in young adults, and investigated the influence of skin pigmentation (M-index) on measurement accuracy. Simultaneous 3 min Kairos and ECG samples were obtained in the supine (n = 32) and seated (n = 30) position. Comparisons included resting heart rate (RHR) and time domain (root-mean square of successive differences [RMSSD], standard deviation of normal RR intervals [SDNN]), frequency domain (low [LF] and high frequency [HF]), and non-linear (standard deviation 1 [SD1] and SD2) HRV metrics. RHR showed excellent agreement whereas HF, LF, and SD2 showed poor agreement. For the remaining metrics, SDNN showed the strongest absolute and relative agreement, followed by SD1 and RMSSD. However, most HRV metrics exhibited heteroscedasticity or proportional bias, with greater error and underestimation at higher HRV values. M-index was unrelated to method difference scores, except for seated SD2 (p = 0.01). The Kairos wristband can be used to measure RHR, but HRV assessment should be limited to SDNN for global variability and SD1 or RMSSD for cardiac–parasympathetic activity. However, these metrics should be interpreted within the level of agreement identified in this study, and with consideration of the observed trend of diminished accuracy with higher HRV values.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateElectrocardiographyWearable Electronic DevicesHumansMaleFemaleAdultYoung AdultWristRest

Stichwörter der Autor:innen

autonomic nervous systemcardiovasculardevice validationm-healthwearable technology

Autor:innen und Institutionen

  • Biodynamics and Human Performance Center, Department of Health Sciences and Kinesiology, Georgia Southern University, Armstrong Campus, 11935 Abercorn St., Savannah, GA 31419, USA.

ORCID-Profile: Andrew A Flatt, Ann Claire E Blalock, Bryan L Riemann

Förderung

  • Biostrap USA LLC

Zitieren

APA

Flatt, A. A., Blalock, A. C. E., Wade, A. N., & Riemann, B. L. (2025). Biostrap Kairos Wristband Versus Electrocardiography for Resting Heart Rate Variability Assessment. Sensors. https://doi.org/10.3390/s25103165

Vancouver

Flatt AA, Blalock ACE, Wade AN, Riemann BL. Biostrap Kairos Wristband Versus Electrocardiography for Resting Heart Rate Variability Assessment. Sensors. 2025. doi:10.3390/s25103165

BibTeX
@article{Flatt2025,
  author = {Flatt, Andrew A and Blalock, Ann Claire E and Wade, Allison N and Riemann, Bryan L},
  title = {Biostrap Kairos Wristband Versus Electrocardiography for Resting Heart Rate Variability Assessment},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25103165}
}
Kostenlos starten →