EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor

Sheik Mohammed Ali, Sridhar Poosapadi Arjunan iD, James Peter, Laura Perju-Dumbrava, Catherine Ding, Michael Eller, Sanjay Raghav, Peter Kempster iD, Mohammod Abdul Motin iD, P J Radcliffe, Dinesh Kant Kumar iD

IEEE Journal of Translational Engineering in Health and Medicine · 2024 · 12 · 194-203

DOI: 10.1109/jtehm.2023.3329344 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Translational Engineering in Health and Medicine, 2024. Verfasst von Sheik Mohammed Ali und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Biomedical EngineeringRMIT University Melbourne VIC 3000 Australia. Hauptthemen laut MEDLINE: Essential Tremor, Wearable Electronic Devices. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Scheme for Promotion of Academic and Research Collaboration, Stiftelsen Promobilia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Several validated clinical scales measure the severity of essential tremor (ET). Their assessments are subjective and can depend on familiarity and training with scoring systems. METHOD: We propose a multi-modal sensing using a wearable inertial measurement unit for estimating scores on the Fahn-Tolosa-Marin tremor rating scale (FTM) and determine the classification accuracy within the tremor type. 17 ET participants and 18 healthy controls were recruited for the study. Two movement disorder neurologists who were blinded to prior clinical information viewed video recordings and scored the FTM. Participants drew a guided Archimedes spiral while wearing an inertial measurement unit placed at the mid-point between the lateral epicondyle of the humerus and the anatomical snuff box. Acceleration and gyroscope recordings were analyzed. The ratio of the power spectral density between frequency bands 0.5-4 Hz and 4-12 Hz, and the sum of power spectrum density over the entire spectrum of 2-74 Hz, for both accelerometer and gyroscope data, were computed. FTM was estimated using regression model and classification using SVM was validated using the leave-one-out method. RESULTS: Regression analysis showed a moderate to good correlation when individual features were used, while correlation was high ([Formula: see text] = 0.818) when suitable features of the gyro and accelerometer were combined. The accuracy for two-class classification of the combined features using SVM was 91.42% while for four-class it was 68.57%. CONCLUSION: Potential applications of this novel wearable sensing method using a wearable Inertial Measurement Unit (IMU) include monitoring of ET and clinical trials of new treatments for the disorder.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Essential TremorWearable Electronic DevicesHumansTremorAccelerationAccelerometry

Stichwörter der Autor:innen

Essential tremorFahn-Tolosa-Marin tremor rating scaleinertial measurement unitwearables

Autor:innen und Institutionen

  • Department of Electrical and Biomedical EngineeringRMIT University Melbourne VIC 3000 Australia.
  • SRM Institute of Science and Technology Chennai 603203 India.
  • Neurosciences DepartmentMonash Health Clayton VIC 3168 Australia.
  • Department of MedicineSchool of Clinical SciencesMonash University Clayton VIC 3800 Australia.
  • Department of Electrical and Electronic EngineeringRajshahi University of Engineering and Technology Rajshahi 6204 Bangladesh.

ORCID-Profile: Sridhar Poosapadi Arjunan, Peter Kempster, Mohammod Abdul Motin, Dinesh Kant Kumar

Förderung

  • Scheme for Promotion of Academic and Research Collaboration
  • Stiftelsen Promobilia

Zitieren

APA

Ali, S. M., Arjunan, S. P., Peter, J., Perju-Dumbrava, L., Ding, C., Eller, M., Raghav, S., Kempster, P., Motin, M. A., Radcliffe, P. J., & Kumar, D. K. (2024). Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor. IEEE Journal of Translational Engineering in Health and Medicine, 12, 194-203. https://doi.org/10.1109/jtehm.2023.3329344

Vancouver

Ali SM, Arjunan SP, Peter J, Perju-Dumbrava L, Ding C, Eller M, et al. Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor. IEEE Journal of Translational Engineering in Health and Medicine. 2024;12:194-203. doi:10.1109/jtehm.2023.3329344

BibTeX
@article{Ali2024,
  author = {Ali, Sheik Mohammed and Arjunan, Sridhar Poosapadi and Peter, James and Perju-Dumbrava, Laura and Ding, Catherine and Eller, Michael and Raghav, Sanjay and Kempster, Peter and Motin, Mohammod Abdul and Radcliffe, P J and Kumar, Dinesh Kant},
  title = {Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor},
  journal = {IEEE Journal of Translational Engineering in Health and Medicine},
  year = {2024},
  volume = {12},
  pages = {194--203},
  doi = {10.1109/jtehm.2023.3329344}
}
Kostenlos starten →