A Thin Embedded FBG Instrumented Wafer for In Situ Temperature Monitoring and Wafer-Scale Temperature Mapping
IEEE Sensors Journal · 2026-11 · 26 (21) · 32349-32357
DOI: 10.1109/jsen.2026.3734040 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-11. Verfasst von Yuhao Feng und 6 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Accurate wafer-level temperature monitoring is critical for thermal-process control and equipment calibration in microelectromechanical systems (MEMSs) and semiconductor manufacturing, yet conventional electrically interrogated instrumented wafers (IWs) can be limited by electromagnetic susceptibility, electrical drift, self-heating, and long-term stability issues in practical process environments. This article presents a thin embedded fiber Bragg grating IW (FBG-IW) for in situ multipoint temperature monitoring and wafer-level temperature-field reconstruction. The proposed device adopts a three-layer architecture consisting of a laser-machined substrate wafer, an embedded FBG sensing network, and an ultrathin cover wafer. A total of 29 FBG sensing points are integrated into the wafer while maintaining an overall thickness below 1 mm, enabling compact wafer-compatible optical temperature measurement. After encapsulation, the embedded FBG array exhibits linear and consistent wavelength-to-temperature responses. During heating–soaking–cooling experiments, the FBG-IW provides real-time multipoint temperature tracking, and resistance temperature detector (RTD)-referenced validation shows that the measurement error remains within $\pm 0.55~^{\circ }$ C under the tested thermal conditions. Wafer-level temperature fields are further reconstructed from the sparse embedded measurements using Gaussian radial basis function (GRBF) interpolation. Leave-one-out cross-validation (LOOCV) yields a mean absolute error (MAE) of $0.49~^{\circ }$ C and a root-mean-square error of $0.68~^{\circ }$ C. These results demonstrate that the proposed FBG-IW offers an electrically passive, compact, and wafer-compatible sensing platform for in situ temperature monitoring, equipment calibration, and temperature-field diagnosis in wafer-level manufacturing.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Feng, Y., Wu, T., Peng, J., Peng, Y., Xing, F., Sun, T., & Zhang, Y. (2026). A Thin Embedded FBG Instrumented Wafer for In Situ Temperature Monitoring and Wafer-Scale Temperature Mapping. IEEE Sensors Journal, 26(21), 32349-32357. https://doi.org/10.1109/jsen.2026.3734040
Vancouver
Feng Y, Wu T, Peng J, Peng Y, Xing F, Sun T, et al. A Thin Embedded FBG Instrumented Wafer for In Situ Temperature Monitoring and Wafer-Scale Temperature Mapping. IEEE Sensors Journal. 2026;26(21):32349-32357. doi:10.1109/jsen.2026.3734040
BibTeX
@article{Feng2026,
author = {Feng, Yuhao and Wu, Tao and Peng, Jingjing and Peng, Yicheng and Xing, Fei and Sun, Ting and Zhang, Yang},
title = {A Thin Embedded FBG Instrumented Wafer for In Situ Temperature Monitoring and Wafer-Scale Temperature Mapping},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {21},
pages = {32349--32357},
doi = {10.1109/jsen.2026.3734040}
}