EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In Situ Temperature Monitoring of Superconducting Cables in Liquid Nitrogen via a Centerline-Deployed FBG Array

Xinyu Chen, Jinquan Yu, Tingting Li, Huan Gao, Xin Gui, Min Zhu, Jiaqi Wang, Zhengying Li

Photonics · 17.04.2026 · 13 (4) · 389

DOI: 10.3390/photonics13040389 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics, online erschienen am 17.04.2026. Verfasst von Xinyu Chen und 7 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Commission of Shanghai Municipality, National Natural Science Foundation of China, Hubei Provincial Department of Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reliable in situ temperature monitoring is essential for the safe operation of liquid-nitrogen-cooled superconducting cables, yet conventional electrical sensors are often difficult to scale to multi-point deployment in cryogenic, high-current environments. This work presents a fiber Bragg grating (FBG) sensing solution for in situ temperature monitoring of superconducting cables in liquid nitrogen. An FBG array packaged with a polyimide-coated fiber inside a 3 mm stainless-steel tube is deployed along the cable centerline to provide multi-point temperature measurements of the cable core. The system is validated under liquid-nitrogen immersion with a 2000 A current turn-on/turn-off test, with a 1 Hz update rate and a steady-state temperature fluctuation within ±0.1 °C. Experimental results show a continuous temperature decrease during liquid-nitrogen cooling, followed by a cryogenic plateau, during which a spatially consistent 0.6–0.7 °C current-induced temperature rise is observed across multiple sensing points in the present 2000 A turn-on/turn-off test, followed by recovery after current shutoff. Small-amplitude fluctuations during the plateau are attributed to packaging-dependent thermal coupling between the centerline-deployed sensor and the cable core. These results indicate that the proposed FBG-based approach enables reliable cryogenic thermometry for superconducting cables in liquid nitrogen and provides a practical tool for in situ operational condition assessment.

Förderung

  • Science and Technology Commission of Shanghai Municipality
  • National Natural Science Foundation of China
  • Hubei Provincial Department of Science and Technology

Zitieren

APA

Chen, X., Yu, J., Li, T., Gao, H., Gui, X., Zhu, M., Wang, J., & Li, Z. (2026). In Situ Temperature Monitoring of Superconducting Cables in Liquid Nitrogen via a Centerline-Deployed FBG Array. Photonics, 13(4), 389. https://doi.org/10.3390/photonics13040389

Vancouver

Chen X, Yu J, Li T, Gao H, Gui X, Zhu M, et al. In Situ Temperature Monitoring of Superconducting Cables in Liquid Nitrogen via a Centerline-Deployed FBG Array. Photonics. 2026;13(4):389. doi:10.3390/photonics13040389

BibTeX
@article{Chen2026,
  author = {Chen, Xinyu and Yu, Jinquan and Li, Tingting and Gao, Huan and Gui, Xin and Zhu, Min and Wang, Jiaqi and Li, Zhengying},
  title = {In Situ Temperature Monitoring of Superconducting Cables in Liquid Nitrogen via a Centerline-Deployed FBG Array},
  journal = {Photonics},
  year = {2026},
  volume = {13},
  number = {4},
  pages = {389},
  doi = {10.3390/photonics13040389}
}