EUVIMEDEUVIMED entdecken
Crossref

Multiparameter Detection Technology for Temperature and Partial Discharge in Liquid–Solid Composite Dielectrics Based on DFB-FL

Jixian Qiao, Chao Du, Weichao Zhang, Lisheng Zhong, Qibing Shao, Hong Zhao

IEEE Sensors Journal · 01.05.2026 · 26 (9) · 13137-13144

DOI: 10.1109/jsen.2026.3675128 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.05.2026. Verfasst von Jixian Qiao und 5 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Heilongjiang Provincial Natural Science Foundation Key Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traditional fiber optic sensors used for operation and maintenance inspection of power equipment face challenges in achieving multiparameter detection due to factors such as sensitivity, safety, detection range, reusability, and difficulty in spatial separation from the demodulation system. Distributed feedback fiber laser (DFB-FL) exhibits extremely high detection sensitivity to strain due to its ultra-narrow emission linewidth. Moreover, its small size, high safety, excellent reusability, and independent demodulation systems can effectively solve the aforementioned problems. Based on the ultimate frequency noise and acoustic pressure model, the minimum measurable acoustic pressure of DFB-FL in the partial discharge (PD) acoustic emission frequency band is derived. The relationship between the center wavelength of DFB-FL and external temperature changes is explored based on the temperature sensitivity characteristics of DFB-FL. A multiparameter detection system for PD acoustic emission and temperature based on DFB-FL is developed. The results of 80 kVA oil-immersed transformer temperature and PD detection show that the developed DFB-FL multiparameter detection system can be effectively applied to measure the top-oil temperature (TOT) and hot-spot temperature (HST) of oil-immersed transformers. Meanwhile, under the same PD ultrasonic excitation source, the average maximum response SNR of the system is 13.71 dB higher than that of a piezoelectric transducer (PZT).

Förderung

  • National Natural Science Foundation of China
  • Heilongjiang Provincial Natural Science Foundation Key Project

Zitieren

APA

Qiao, J., Du, C., Zhang, W., Zhong, L., Shao, Q., & Zhao, H. (2026). Multiparameter Detection Technology for Temperature and Partial Discharge in Liquid–Solid Composite Dielectrics Based on DFB-FL. IEEE Sensors Journal, 26(9), 13137-13144. https://doi.org/10.1109/jsen.2026.3675128

Vancouver

Qiao J, Du C, Zhang W, Zhong L, Shao Q, Zhao H. Multiparameter Detection Technology for Temperature and Partial Discharge in Liquid–Solid Composite Dielectrics Based on DFB-FL. IEEE Sensors Journal. 2026;26(9):13137-13144. doi:10.1109/jsen.2026.3675128

BibTeX
@article{Qiao2026,
  author = {Qiao, Jixian and Du, Chao and Zhang, Weichao and Zhong, Lisheng and Shao, Qibing and Zhao, Hong},
  title = {Multiparameter Detection Technology for Temperature and Partial Discharge in Liquid–Solid Composite Dielectrics Based on DFB-FL},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {9},
  pages = {13137--13144},
  doi = {10.1109/jsen.2026.3675128}
}
Kostenlos starten →