Research on Electro-Acoustic Synergistic Partial Discharge Detection Technology for Cable Terminations
Sensors · 30.05.2026 · 26 (11) · 3460
DOI: 10.3390/s26113460 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 30.05.2026. Verfasst von Cong Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: China Power Huachuang (Suzhou) Electricity Technology Research Co., Ltd., Suzhou 215123, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Power Investment Corporation (China), STATE POWER INVESTMENT CORPORATION LIMITED.
Abstract (Originalsprache)
To address the limited spatial localization accuracy of partial discharge (PD) in high-voltage cable terminations and the difficulty in accurately determining the trigger time in traditional ultrasonic detection, this paper proposes an electro-acoustic synergistic localization technology based on a high-frequency current transformer (HFCT) and a Sagnac optical fiber interferometer. A high-sensitivity Sagnac acoustic sensor based on a 3D-printed photosensitive resin mandrel was developed. Through structural design and 0–50 kHz amplitude–frequency testing, the sensor exhibits a dominant resonant response at 33.2 kHz. This narrow-band, high-sensitivity characteristic effectively enhances the perception capability for weak PD ultrasonic signals. An electro-acoustic synergistic detection system was constructed, in which the high-frequency PD current signal captured by the HFCT was used as the electrical time reference, and a dual-channel Sagnac sensor array was used to extract the arrival times of ultrasonic waves. In a 12 kV laboratory cable-termination PD experiment, the proposed system identified the representative built-in air-gap PD source with an absolute localization error of 5 mm under the tested laboratory configuration. This value should be interpreted as the localization result for the tested representative defect, rather than as a generally validated accuracy specification of the system. This study provides a proof-of-concept laboratory demonstration of an electro-acoustic localization strategy that combines the fast electrical response of HFCT detection with the electromagnetic-interference immunity and acoustic sensitivity of Sagnac fiber-optic sensing.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- China Power Huachuang (Suzhou) Electricity Technology Research Co., Ltd., Suzhou 215123, China.
- State Key Laboratory of High-Efficiency Special Cable Technology, Harbin University of Science and Technology, Harbin 150080, China.
ORCID-Profile: Qichao Chen
Förderung
- State Power Investment Corporation (China)
- STATE POWER INVESTMENT CORPORATION LIMITED
Zitieren
APA
Chen, C., Wang, X., Li, Y., & Chen, Q. (2026). Research on Electro-Acoustic Synergistic Partial Discharge Detection Technology for Cable Terminations. Sensors, 26(11), 3460. https://doi.org/10.3390/s26113460
Vancouver
Chen C, Wang X, Li Y, Chen Q. Research on Electro-Acoustic Synergistic Partial Discharge Detection Technology for Cable Terminations. Sensors. 2026;26(11):3460. doi:10.3390/s26113460
BibTeX
@article{Chen2026,
author = {Chen, Cong and Wang, Xiaojian and Li, Yanju and Chen, Qichao},
title = {Research on Electro-Acoustic Synergistic Partial Discharge Detection Technology for Cable Terminations},
journal = {Sensors},
year = {2026},
volume = {26},
number = {11},
pages = {3460},
doi = {10.3390/s26113460}
}
EUVIMED