EUVIMEDEUVIMED entdecken
Crossref

A Self-Reference Multi-Channel Optical Fiber Microcavity Biosensor for SARS-CoV-2 Detection

Jianwei Huang, Zhi Chen, Wenyu Wang, Shaoxiang Duan, Yan Zhang, Yuan Zhang, Hao Zhang, Bo Liu

Journal of Lightwave Technology · 15.07.2026 · 44 (14) · 6320-6328

DOI: 10.1109/jlt.2026.3698124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Lightwave Technology, erschienen am 15.07.2026. Verfasst von Jianwei Huang und 7 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, Tianjin Natural Science Foundation Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The false-positive problem in biosensing significantly compromises detection accuracy. Herein, we present a multi-channel optical fiber microcavity biosensor designed to suppress false-positive responses, which is demonstrated through the quantitative detection and analysis of SARS-CoV-2. The fabrication of sensor accomplished by encapsulating optical fiber Fabry-Perot (FP) interferometer, followed by antibody functionalization. This approach enables the quantitative and specific detection of SARS-CoV-2 through real-time monitoring the interference spectrum wavelength shift. The sensor was designed with three detection channels (experimental, parallel, and control) for the simultaneous detection of SARS-CoV-2. The parallel channel was used to validate the detection accuracy of experimental channel, while the control channel was employed to identify and eliminate false positives caused by non-specific adsorption, which enabled the self-referencing function of the sensor. The experimental results demonstrated that the sensor exhibited a linear sensitivity of 0.493 nm/(μg/mL) for the SARS-CoV-2 recombinant protein antigen, with a detection limit of 32.4 ng/mL and good specificity. Both the parallel and control channels confirmed the sensor’s reliability: the former verified detection accuracy by showing comparable results, and the latter enabled the elimination of false positives by providing a correction baseline for non-specific binding.

Förderung

  • National Key R&D Program of China
  • National Natural Science Foundation of China
  • Tianjin Natural Science Foundation Project
  • Tianjin Development Program for Innovation and Entrepreneurship
  • Fundamental Research Funds for the Central Universities
  • Nankai University
  • TCL Young Scholars Program

Zitieren

APA

Huang, J., Chen, Z., Wang, W., Duan, S., Zhang, Y., Zhang, Y., Zhang, H., & Liu, B. (2026). A Self-Reference Multi-Channel Optical Fiber Microcavity Biosensor for SARS-CoV-2 Detection. Journal of Lightwave Technology, 44(14), 6320-6328. https://doi.org/10.1109/jlt.2026.3698124

Vancouver

Huang J, Chen Z, Wang W, Duan S, Zhang Y, Zhang Y, et al. A Self-Reference Multi-Channel Optical Fiber Microcavity Biosensor for SARS-CoV-2 Detection. Journal of Lightwave Technology. 2026;44(14):6320-6328. doi:10.1109/jlt.2026.3698124

BibTeX
@article{Huang2026,
  author = {Huang, Jianwei and Chen, Zhi and Wang, Wenyu and Duan, Shaoxiang and Zhang, Yan and Zhang, Yuan and Zhang, Hao and Liu, Bo},
  title = {A Self-Reference Multi-Channel Optical Fiber Microcavity Biosensor for SARS-CoV-2 Detection},
  journal = {Journal of Lightwave Technology},
  year = {2026},
  volume = {44},
  number = {14},
  pages = {6320--6328},
  doi = {10.1109/jlt.2026.3698124}
}
Kostenlos starten →