Fachartikel in der Zeitschrift Sensors, online erschienen am 20.05.2024. Verfasst von Yusuke Uchida und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Engineering, Yokohama National University, 79-5 Tokiwada, Hodogaya-ku, Yokohama 240-8501, Japan. Hauptthemen laut MEDLINE: Biosensing Techniques, Silicon, SARS-CoV-2, Coronavirus Nucleocapsid Proteins. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Culture, Sports, Science and Technology, ARIM Japan.
Abstract (Originalsprache)
A high-sensitivity silicon microring (Si MRR) optical biosensor for detecting the nucleocapsid protein of SARS-CoV-2 is proposed and demonstrated. In the proposed biosensor, the surface of a Si MRR waveguide is modified with antibodies, and the target protein is detected by measuring a resonant wavelength shift of the MRR caused by the selective adsorption of the protein to the surface of the waveguide. A Si MRR is fabricated on a silicon-on-insulator substrate using a CMOS-compatible fabrication process. The quality factor of the MRR is approximately 20,000. The resonant wavelength shift of the MRR and the detection limit for the environmental refractive index change are evaluated to be 89 nm/refractive index unit (RIU) and 10−4 RIU, respectively. The sensing characteristics are examined using a polydimethylsiloxane flow channel after the surface of the Si MRR waveguide is modified with the IgG antibodies through the Si-tagged protein. First, the selective detection of the protein by the MRR sensor is experimentally demonstrated by the detection of bovine serum albumin and human serum albumin. Next, various concentrations of nucleocapsid protein solutions are measured by the MRR, in which the waveguide surface is modified with the IgG antibodies through the Si-tagged protein. Although the experimental results are very preliminary, they show that the proposed sensor has a potential nucleocapsid sensitivity in the order of 10 pg/mL, which is comparable to the sensitivity of current antigen tests. The detection time is less than 10 min, which is much shorter than those of other antigen tests.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Graduate School of Engineering, Yokohama National University, 79-5 Tokiwada, Hodogaya-ku, Yokohama 240-8501, Japan.
- System Design Lab, School of Engineering, The University of Tokyo, 2-11-16, Yayoi, Bunkyo-ku, Tokyo 113-0032, Japan.
- Department of Science and Engineering, Kanto Gakuin University, 1-50-1 Mutsuura-higashi, Kanazawa-ku, Yokohama 236-8501, Japan.
ORCID-Profile: Taro Arakawa, Akio Higo
Förderung
- Ministry of Education, Culture, Sports, Science and Technology
- ARIM Japan
Zitieren
APA
Uchida, Y., Arakawa, T., Higo, A., & Ishizaka, Y. (2024). Silicon Microring Resonator Biosensor for Detection of Nucleocapsid Protein of SARS-CoV-2. Sensors, 24(10), 3250. https://doi.org/10.3390/s24103250
Vancouver
Uchida Y, Arakawa T, Higo A, Ishizaka Y. Silicon Microring Resonator Biosensor for Detection of Nucleocapsid Protein of SARS-CoV-2. Sensors. 2024;24(10):3250. doi:10.3390/s24103250
BibTeX
@article{Uchida2024,
author = {Uchida, Yusuke and Arakawa, Taro and Higo, Akio and Ishizaka, Yuhei},
title = {Silicon Microring Resonator Biosensor for Detection of Nucleocapsid Protein of SARS-CoV-2},
journal = {Sensors},
year = {2024},
volume = {24},
number = {10},
pages = {3250},
doi = {10.3390/s24103250}
}