EUVIMEDEUVIMED entdecken
Crossref

Temperature Self-Compensated Biosensor Based on No-Core-Fiber Offset Microcavity for Label-Free BSA Detection

Xianchao Yang, Guan Yang, Meize Chen, Bing Chen, Yang Gao, Shuai Sun, Pibin Bing, Yongjun Wu, Xiaonan Yang, Yuhuai Liu, Jianquan Yao

IEEE Transactions on Instrumentation and Measurement · 2024 · 73 · 1-9

DOI: 10.1109/tim.2024.3427796 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2024. Verfasst von Xianchao Yang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Strategic Priority Research Program of the Chinese Academy of Sciences, Science and Technology Research Program of Henan Province, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple Mach-Zehnder interferometer (MZI) induced by no-core-fiber (NCF) offset microcavity is proposed and demonstrated for temperature self-compensated biosensing. The microcavity is fabricated by online fiber cutting-welding method. Benefiting from the directly interact between microfluidics and fiber core signal in microcavity instead of evanescent wave, an ultrahigh RI sensitivity of −12146 nm/RIU was obtained by experiment with a temperature cross-sensitivity of 2.05 nm/°C. The influence of microcavity length was analyzed in detail. Temperature self-compensation can be realized by solving a multivariate matrix. Finally, the bovine serum albumin (BSA) samples in different concentrations were detected to evaluate the biosensing capability. Experiments demonstrated that the designed sensor exhibited a BSA concentration sensitivity of −10.4 nm/mg/mL and a detection limit (DL) of $1.9~\mu $ g/mL, which shows great potential for label-free biochemical trace detections without temperature-induced cross-sensitivity.

Förderung

  • Strategic Priority Research Program of the Chinese Academy of Sciences
  • Science and Technology Research Program of Henan Province
  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Key Program for International Joint Research of Henan Province
  • Ningbo Major Project of “Science, Technology, and Innovation 2025”
  • Zhengzhou 1125 Innovation Project

Zitieren

APA

Yang, X., Yang, G., Chen, M., Chen, B., Gao, Y., Sun, S., Bing, P., Wu, Y., Yang, X., Liu, Y., & Yao, J. (2024). Temperature Self-Compensated Biosensor Based on No-Core-Fiber Offset Microcavity for Label-Free BSA Detection. IEEE Transactions on Instrumentation and Measurement, 73, 1-9. https://doi.org/10.1109/tim.2024.3427796

Vancouver

Yang X, Yang G, Chen M, Chen B, Gao Y, Sun S, et al. Temperature Self-Compensated Biosensor Based on No-Core-Fiber Offset Microcavity for Label-Free BSA Detection. IEEE Transactions on Instrumentation and Measurement. 2024;73:1-9. doi:10.1109/tim.2024.3427796

BibTeX
@article{Yang2024,
  author = {Yang, Xianchao and Yang, Guan and Chen, Meize and Chen, Bing and Gao, Yang and Sun, Shuai and Bing, Pibin and Wu, Yongjun and Yang, Xiaonan and Liu, Yuhuai and Yao, Jianquan},
  title = {Temperature Self-Compensated Biosensor Based on No-Core-Fiber Offset Microcavity for Label-Free BSA Detection},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2024},
  volume = {73},
  pages = {1--9},
  doi = {10.1109/tim.2024.3427796}
}
Kostenlos starten →