Radiation protection strategies for FLASH radiotherapy accelerator installation in animal housing
Radiation Protection Dosimetry · 02.11.2026 · 202 (18) · 1508-1523
DOI: 10.1093/rpd/ncag079 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 10.08.2026. Verfasst von Giorgio Russo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Bioimaging and Complex Biological Systems, National Research Council (IBSBC-CNR), Via Terzo Millennio 1 Cefalù, Palermo 90015, Italy. Hauptthemen laut MEDLINE: Radiation Protection, Particle Accelerators, Housing, Animal, Radiation Monitoring. Die Arbeit nennt 37 Literaturangaben. Gefördert von: GIOCONDA project, AdvaNced Technologies for Human-centrEd Medicine, Italian National Recovery and Resilience Plan.
Abstract (Originalsprache)
This study presents a radioprotection assessment for an ultra-high dose rate accelerator installation in one of the animal housing of the Centre for Advanced Preclinical in vivo Research. The main problem concerns the absence of a bunker while limiting exposure in nearby work areas. The geometry of the accelerator, the building layouts and the distribution of the environmental dose equivalent were simulated with FLUKA.CERN 4–4.1, modeling a 9 MeV electron beam. The results confirmed compliance with the limit of 0.250 mSv/year for unrestricted areas during daytime operation. Night-time operating zone restrictions apply when no staff are present, allowing beam on for quality controls. The effective doses to the population, researchers and workers are less than 1 mSv/year, in accordance with Legislative Decree 101/2020; the accelerator operators are classified as exposed. For small animals, precautionary dose limit of 1 mSv/year was adopted. The use of lead shielding and site-specific safety measures ensure radiological compliance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Institute of Bioimaging and Complex Biological Systems, National Research Council (IBSBC-CNR), Via Terzo Millennio 1 Cefalù, Palermo 90015, Italy.
- INFN-Laboratorio Nazionale del Sud, Via Santa Sofia, Catania 95123, Italy.
- Department of physics "Ettore Majorana", University of Catania, Via Santa Sofia 64, Catania 95123, Italy.
- Department of Biomedical and Biotechnological Sciences, University of Catania, Via Santa Sofia 89, Catania 95123, Italy.
ORCID-Profile: Santa Gabriella Bonaccorsi
Förderung
- GIOCONDA project
- AdvaNced Technologies for Human-centrEd Medicine
- Italian National Recovery and Resilience Plan
- National Biodiversity Future Center 1
Zitieren
APA
Russo, G., Bonaccorsi, S. G., Leanza, R., Costa, M., Pucci, G., Alberghina, C., Cammarata, F. P., Volti, G. L., & Parenti, R. (2026). Radiation protection strategies for FLASH radiotherapy accelerator installation in animal housing. Radiation Protection Dosimetry, 202(18), 1508-1523. https://doi.org/10.1093/rpd/ncag079
Vancouver
Russo G, Bonaccorsi SG, Leanza R, Costa M, Pucci G, Alberghina C, et al. Radiation protection strategies for FLASH radiotherapy accelerator installation in animal housing. Radiation Protection Dosimetry. 2026;202(18):1508-1523. doi:10.1093/rpd/ncag079
BibTeX
@article{Russo2026,
author = {Russo, Giorgio and Bonaccorsi, Santa Gabriella and Leanza, Renata and Costa, Maria and Pucci, Gaia and Alberghina, Cristiana and Cammarata, Francesco Paolo and Volti, Giovanni Li and Parenti, Rosalba},
title = {Radiation protection strategies for FLASH radiotherapy accelerator installation in animal housing},
journal = {Radiation Protection Dosimetry},
year = {2026},
volume = {202},
number = {18},
pages = {1508--1523},
doi = {10.1093/rpd/ncag079}
}
EUVIMED