EUVIMEDEUVIMED entdecken
Vergleichsstudie

Performance of personal dosimetry systems in India: insights from EURADOS interlaboratory comparison exercises IC2022ph and IC2022n

Suresh M Pradhan iD, Madhumita Bhattacharya iD, Munir S Pathan, Rupali Pal, Sandipan Dawn, Kshama Srivastava iD, Ashok K Bakshi, T Palani Selvam iD, Balvinder K Sapra

Radiation Protection Dosimetry · 2025

DOI: 10.1093/rpd/ncaf074 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Suresh M Pradhan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India. Hauptthemen laut MEDLINE: Thermoluminescent Dosimetry, Occupational Exposure, Radiation Protection, Radiation Monitoring. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bhabha Atomic Research Centre participated in the EURADOS Inter-comparison Exercises IC2022ph [Hp(10) and Hp(0.07)] and IC2022n [Hp(10] for assessment of external exposures, using the CaSO4:Dy-based thermoluminescent dosemeter (TLD) (indigenously developed) for photon and beta radiations and etched track neutron dosemeter, respectively. The performance of TLD personnel dosimetry system, assessed in accordance with ISO 14146:2018 and ANSI N13-11.2009 standards, is satisfactory. The results of the IC2022ph have enhanced confidence in the accuracy and reliability of the Hp(10) and Hp(0.07) algorithms used for TLD badge. Dose evaluation for the neutron dosimetry system was based on in-house developed imaging system. The performance of neutron dosemeter system, as assessed in this interlaboratory comparison, indicates a need to improve the quality of the detector material. Participation in the inter-comparison exercises underscores the reliability of dosimetry systems and highlights their effectiveness in accurately assessing external radiation exposures in India’s personnel monitoring programs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thermoluminescent DosimetryOccupational ExposureRadiation ProtectionRadiation MonitoringRadiometryIndiaHumansNeutronsReproducibility of ResultsRadiation DosageAlgorithmsPhotons

Autor:innen und Institutionen

  • Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India.
  • Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094, India.

ORCID-Profile: Suresh M Pradhan, Madhumita Bhattacharya, Kshama Srivastava, T Palani Selvam

Zitieren

APA

Pradhan, S. M., Bhattacharya, M., Pathan, M. S., Pal, R., Dawn, S., Srivastava, K., Bakshi, A. K., Selvam, T. P., & Sapra, B. K. (2025). Performance of personal dosimetry systems in India: insights from EURADOS interlaboratory comparison exercises IC2022ph and IC2022n. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf074

Vancouver

Pradhan SM, Bhattacharya M, Pathan MS, Pal R, Dawn S, Srivastava K, et al. Performance of personal dosimetry systems in India: insights from EURADOS interlaboratory comparison exercises IC2022ph and IC2022n. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf074

BibTeX
@article{Pradhan2025,
  author = {Pradhan, Suresh M and Bhattacharya, Madhumita and Pathan, Munir S and Pal, Rupali and Dawn, Sandipan and Srivastava, Kshama and Bakshi, Ashok K and Selvam, T Palani and Sapra, Balvinder K},
  title = {Performance of personal dosimetry systems in India: insights from EURADOS interlaboratory comparison exercises IC2022ph and IC2022n},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf074}
}
Kostenlos starten →