Occupational dose measurement in interventional cardiology practice
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae072 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Sachini Udara Wickramasinghe und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Allied Health Sciences, General Sir John Kotelawala Defence University, Ratmalana, Sri Lanka. Hauptthemen laut MEDLINE: Occupational Exposure, Radiation Dosage, Radiation Protection, Cardiology. Die Arbeit nennt 31 Literaturangaben. Gefördert von: General Sir John Kotelawala Defence University.
Abstract (Originalsprache)
Ensuring the safety of healthcare workers in interventional cardiology necessitates effective monitoring of occupational radiation exposure. This study aims to assess the accuracy of the over-apron single dosimetric approach compared with double dosimetric methods and explore the relationship between under-apron and over-apron doses. This investigation showed that the prescribed annual dose constraint of 20 mSv year−1 was not exceeded by the maximum annual occupational doses determined by dosimetric algorithms, which were 0.13 ± 0.02, 0.15 ± 0.02 and 0.27 ± 0.04 mSv, respectively. The study demonstrated excellent statistically significant correlations among single and double dosimetric algorithms and between direct under-apron and over-apron doses. Consequently, single dosimetric algorithms could effectively estimate doses for double dosimetric algorithms, highlighting the limited added value of under-apron measurements. These findings significantly impact the practice of interventional cardiology in Sri Lanka, playing a crucial role in enhancing radiation protection measures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Faculty of Allied Health Sciences, General Sir John Kotelawala Defence University, Ratmalana, Sri Lanka.
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.
- School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia.
- Institute of Cardiology, National Hospital, Colombo, Sri Lanka.
ORCID-Profile: Sachini Udara Wickramasinghe, Vijitha Ramanathan, Sivananthan Sarasanandarajah
Förderung
- General Sir John Kotelawala Defence University
Zitieren
APA
Wickramasinghe, S. U., Ramanathan, V., Sarasanandarajah, S., De Zoyza, M., & Paranamana, R. (2024). Occupational dose measurement in interventional cardiology practice. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae072
Vancouver
Wickramasinghe SU, Ramanathan V, Sarasanandarajah S, De Zoyza M, Paranamana R. Occupational dose measurement in interventional cardiology practice. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae072
BibTeX
@article{Wickramasinghe2024,
author = {Wickramasinghe, Sachini Udara and Ramanathan, Vijitha and Sarasanandarajah, Sivananthan and De Zoyza, Manjuka and Paranamana, Roshan},
title = {Occupational dose measurement in interventional cardiology practice},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae072}
}
EUVIMED