EUVIMEDEUVIMED entdecken
Crossref

Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range

Tomoya Tsuji iD, Hiroshi Yoshitomi, Munehiko Kowatari iD, Fuminobu Sato, Yoshihiko Tanimura iD

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncag002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Tomoya Tsuji und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-…. Hauptthemen laut MEDLINE: Photons, Gamma Rays, Radiation Monitoring, Radiation Protection. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A γ-ray calibration field using a sealed 133Ba source for photon energy in the 300–400 keV range was established at the Japan Atomic Energy Agency to evaluate radiation protection devices under low dose rate conditions. To suppress low-energy γ-ray components, a 2-mm lead filter was applied. The photon fluence spectrum was measured using a CdTe spectrometer and an unfolding method, yielding a spectrum with a mean energy of 321 keV. Reference air kerma rates were determined using ionization chambers calibrated in a 137Cs field, with energy correction factors applied. Spectrometry using a CeBr₃ scintillation spectrometer combined with the G(E) function method was employed to validate these corrections. Spectrum-averaged conversion coefficients were derived from the measured spectrum, indicating equivalence to the N-400 radiation quality. This field provided air kerma rates from 0.22 to 2.13 μGy h−1, suitable for testing devices used in environmental monitoring and nuclear emergency response.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotonsGamma RaysRadiation MonitoringRadiation ProtectionCalibrationRadiation DosageJapan

Autor:innen und Institutionen

  • Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, Japan.
  • Department of Radiation Measurement and Dose Assessment, National Institute for Radiological Sciences, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.
  • Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan.

ORCID-Profile: Tomoya Tsuji, Munehiko Kowatari, Yoshihiko Tanimura

Zitieren

APA

Tsuji, T., Yoshitomi, H., Kowatari, M., Sato, F., & Tanimura, Y. (2026). Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag002

Vancouver

Tsuji T, Yoshitomi H, Kowatari M, Sato F, Tanimura Y. Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag002

BibTeX
@article{Tsuji2026,
  author = {Tsuji, Tomoya and Yoshitomi, Hiroshi and Kowatari, Munehiko and Sato, Fuminobu and Tanimura, Yoshihiko},
  title = {Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncag002}
}
Kostenlos starten →