Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range
Radiation Protection Dosimetry · 2026
DOI: 10.1093/rpd/ncag002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Tomoya Tsuji und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-…. Hauptthemen laut MEDLINE: Photons, Gamma Rays, Radiation Monitoring, Radiation Protection. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
A γ-ray calibration field using a sealed 133Ba source for photon energy in the 300–400 keV range was established at the Japan Atomic Energy Agency to evaluate radiation protection devices under low dose rate conditions. To suppress low-energy γ-ray components, a 2-mm lead filter was applied. The photon fluence spectrum was measured using a CdTe spectrometer and an unfolding method, yielding a spectrum with a mean energy of 321 keV. Reference air kerma rates were determined using ionization chambers calibrated in a 137Cs field, with energy correction factors applied. Spectrometry using a CeBr₃ scintillation spectrometer combined with the G(E) function method was employed to validate these corrections. Spectrum-averaged conversion coefficients were derived from the measured spectrum, indicating equivalence to the N-400 radiation quality. This field provided air kerma rates from 0.22 to 2.13 μGy h−1, suitable for testing devices used in environmental monitoring and nuclear emergency response.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, Japan.
- Department of Radiation Measurement and Dose Assessment, National Institute for Radiological Sciences, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.
- Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan.
ORCID-Profile: Tomoya Tsuji, Munehiko Kowatari, Yoshihiko Tanimura
Zitieren
APA
Tsuji, T., Yoshitomi, H., Kowatari, M., Sato, F., & Tanimura, Y. (2026). Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag002
Vancouver
Tsuji T, Yoshitomi H, Kowatari M, Sato F, Tanimura Y. Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag002
BibTeX
@article{Tsuji2026,
author = {Tsuji, Tomoya and Yoshitomi, Hiroshi and Kowatari, Munehiko and Sato, Fuminobu and Tanimura, Yoshihiko},
title = {Establishment of a low dose rate 133Ba γ-ray calibration field for photon energy in the 300–400 keV range},
journal = {Radiation Protection Dosimetry},
year = {2026},
doi = {10.1093/rpd/ncag002}
}
EUVIMED