Feasibility of reducing the contrast dose in infants and children with complex congenital heart disease using virtual monoenergetic images on dual-layer spectral detector computed tomography
Pediatric Radiology · 15.04.2026 · 56 (6) · 1348-1358
DOI: 10.1007/s00247-026-06599-x ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Pediatric Radiology, online erschienen am 15.04.2026. Verfasst von Ximing Cao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Heart Defects, Congenital, Contrast Media, Tomography, X-Ray Computed. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Guangdong Basic and Applied Basic Research Foundation.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
BACKGROUND: Virtual monoenergetic imaging (VMI) with dual-layer spectral detector computed tomography (CT) enables keV optimization, offering the potential for contrast dose reduction, particularly beneficial in pediatric imaging. However, its clinical utility in infants and children with complex congenital heart disease (CHD) remains underexplored. OBJECTIVE: To investigate the feasibility of reducing the contrast dose and the optimal keV of virtual monoenergetic images (VMIs) on dual-layer spectral detector CT in infants and children with complex CHD. MATERIALS AND METHODS: Prospectively enrolled 80 infants and children with complex CHD and underwent preoperative dual-layer spectral detector CT. Patients were randomly divided into two groups: group A (n=36, standard dose, 1.5-2 ml/kg) and group B (n=44, low dose, 1 ml/kg). Conventional image and VMIs in range of 40-85 keV were reconstructed in group B while only conventional image was reconstructed in group A. Image quality was evaluated using qualitative scores and objective metrics including CT-value, standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for the pulmonary artery and ascending aorta. RESULTS: Group B received 24% less contrast than group A [8.0 (5.0; 11.0) ml vs. 10.5 (8.0; 21.0) ml, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China.
- Department of Clinical and Technical Support, Philips Healthcare, Guangzhou, China.
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China. lhj0152@126.com.
Förderung
- Guangdong Basic and Applied Basic Research Foundation
Zitieren
APA
Cao, X., Hu, W., Li, J., Liu, X., Liu, H., & Liu, H. (2026). Feasibility of reducing the contrast dose in infants and children with complex congenital heart disease using virtual monoenergetic images on dual-layer spectral detector computed tomography. Pediatric Radiology, 56(6), 1348-1358. https://doi.org/10.1007/s00247-026-06599-x
Vancouver
Cao X, Hu W, Li J, Liu X, Liu H, Liu H. Feasibility of reducing the contrast dose in infants and children with complex congenital heart disease using virtual monoenergetic images on dual-layer spectral detector computed tomography. Pediatric Radiology. 2026;56(6):1348-1358. doi:10.1007/s00247-026-06599-x
BibTeX
@article{Cao2026,
author = {Cao, Ximing and Hu, Wenbin and Li, Jinglei and Liu, Xiaomin and Liu, Hui and Liu, Hongjun},
title = {Feasibility of reducing the contrast dose in infants and children with complex congenital heart disease using virtual monoenergetic images on dual-layer spectral detector computed tomography},
journal = {Pediatric Radiology},
year = {2026},
volume = {56},
number = {6},
pages = {1348--1358},
doi = {10.1007/s00247-026-06599-x}
}
EUVIMED