EUVIMEDEUVIMED entdecken
Crossref

Determination of the ambient dose equivalent H *(10) at high-altitude cities using a NaI(Tl) scintillator

Carlos Lorenzo Nina Choque, Hugo Marcelo Rivera Bretel iD

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae209 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Carlos Lorenzo Nina Choque und 1 weiteren Autor:innen. Beteiligte Einrichtung: Carrera de Física, Facultad de Ciencias Puras y Naturales, Universidad Mayor de San Andrés, Calle 27 Cota Cota, Campus Universitario, La Paz, Bolivia. Hauptthemen laut MEDLINE: Radiation Monitoring, Monte Carlo Method, Gamma Rays, Altitude. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ambient dose equivalent rate H*(10) was determined at various locations in the metropolitan area of the cities of La Paz and El Alto in Bolivia. A NaI(Tl) scintillation detector was employed to infer the gamma-ray fluence, and the fluence was transformed in dose rates by means of the appropriate coefficients. In this paper, a full methodology for the estimation of dose rates associated with gamma rays emitted from the ground (terrestrial radiation) and the atmosphere is developed from measurements made with the scintillator instrument. The energy calibration and resolution of the apparatus are presented, followed by the estimation of its response and efficiency by means of Monte Carlo simulations. Lastly, the definition of H*(10) is used to determine the conversion coefficients needed to transform gamma-ray fluence in dose rates. With this methodology, rates for H*(10) around 123 ± 8 nSv/h were estimated using data collected in three city districts: Mallasa (3320 m a.s.l.), San Antonio (3620 m a.s.l.), and Zona Sur (3400 m a.s.l.). The dose rates are believed to be representative of the terrestrial radiation fields encountered in the highlands of Bolivia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation MonitoringMonte Carlo MethodGamma RaysAltitudeRadiation DosageCitiesBoliviaScintillation CountingAir Pollutants, RadioactiveCalibrationHumansSodium IodideComputer Simulation

Substanzen

Air Pollutants, RadioactiveSodium Iodide

Autor:innen und Institutionen

  • Carrera de Física, Facultad de Ciencias Puras y Naturales, Universidad Mayor de San Andrés, Calle 27 Cota Cota, Campus Universitario, La Paz, Bolivia.

ORCID-Profile: Hugo Marcelo Rivera Bretel

Zitieren

APA

Nina Choque, C. L., & Rivera Bretel, H. M. (2024). Determination of the ambient dose equivalent H *(10) at high-altitude cities using a NaI(Tl) scintillator. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae209

Vancouver

Nina Choque CL, Rivera Bretel HM. Determination of the ambient dose equivalent H *(10) at high-altitude cities using a NaI(Tl) scintillator. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae209

BibTeX
@article{NinaChoque2024,
  author = {Nina Choque, Carlos Lorenzo and Rivera Bretel, Hugo Marcelo},
  title = {Determination of the ambient dose equivalent H *(10) at high-altitude cities using a NaI(Tl) scintillator},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae209}
}
Kostenlos starten →