Determination of neutron spectrum based on artificial neural network using liquid scintillation detector EJ-301

Wan Bo iD, Li Gang, Li Kun, Huang Qichang, Xiong Bangping, Cai Jiao, He Jiaji, Wei Wenbin, Xia Yuan, Yang Daibo

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae189 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Wan Bo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu 610213, China. Hauptthemen laut MEDLINE: Neutrons, Neural Networks, Computer, Monte Carlo Method, Scintillation Counting. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper focuses on the neutron spectrum measurement using a liquid scintillation detector, where the neutron spectrum could be identified and unfolded from the light output distribution of the EJ-301 liquid scintillation detector through a linear artificial neural network (ANN). The response functions of the EJ-301 detector for monoenergetic neutron sources, as well as the light outputs, have been simulated and calculated by Monte Carlo procedure FLUKA. The linear ANN was trained and tested through the simulated data, where response functions were set as the input of ANN and the corresponding neutron spectra were output. Therefore, the neutron spectrum-unfolding model was created. This spectrum-unfolding model was tested through the light outputs induced by monoenergetic neutrons and the random superposition of them. Unfolding results show that this model could identify the information of the neutron spectrum accurately from the light outputs of a liquid scintillation detector. Moreover, the EJ-301 detector was used to measure the radioactivity of 252Cf, and the pulse height distribution induced by neutrons was derived through the charge-comparison method to remove the influence of gamma rays. The measured pulse height distribution was unfolded by the trained model, and measured results show that the unfolded neutron spectrum of 252Cf was consistent with the reference one. This paper presents the feasibility that the unknown neutron spectrum could be identified and confirmed through a linear neural network trained by simulated monoenergetic neutron response functions, which could be a candidate of choice for the determination of the neutron spectrum.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeutronsNeural Networks, ComputerMonte Carlo MethodScintillation CountingCaliforniumComputer SimulationRadiation Dosage

Substanzen

CaliforniumCalifornium-252

Autor:innen und Institutionen

  • Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu 610213, China.

ORCID-Profile: Wan Bo

Zitieren

APA

Bo, W., Gang, L., Kun, L., Qichang, H., Bangping, X., Jiao, C., Jiaji, H., Wenbin, W., Yuan, X., & Daibo, Y. (2024). Determination of neutron spectrum based on artificial neural network using liquid scintillation detector EJ-301. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae189

Vancouver

Bo W, Gang L, Kun L, Qichang H, Bangping X, Jiao C, et al. Determination of neutron spectrum based on artificial neural network using liquid scintillation detector EJ-301. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae189

BibTeX
@article{Bo2024,
  author = {Bo, Wan and Gang, Li and Kun, Li and Qichang, Huang and Bangping, Xiong and Jiao, Cai and Jiaji, He and Wenbin, Wei and Yuan, Xia and Daibo, Yang},
  title = {Determination of neutron spectrum based on artificial neural network using liquid scintillation detector EJ-301},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae189}
}
Kostenlos starten →