Experimental Analysis of Radiation Protection Offered by a Novel Exoskeleton-Based Radiation Protection System versus Conventional Lead Aprons

Maria Katsarou, Bruce Zwiebel, Rajarshi Pal Chowdhury, Murray Shames, Thomas Berger, Bartos Przybyla, Jean Bismuth

Journal of Vascular and Interventional Radiology · 2023

DOI: 10.1016/j.jvir.2023.03.033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vascular and Interventional Radiology, 2023. Verfasst von Maria Katsarou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Houston Methodist DeBakey Heart and Vascular Center, Houston Methodist Hospital, Houston, Texas; Section of Vascular Surgery, Fondazione Istituto di …. Hauptthemen laut MEDLINE: Radiation Protection, Exoskeleton Device, Occupational Exposure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the radiation protection offered by an exoskeleton-based radiation protection system (Stemrad MD) and to compare it with that offered by conventional lead aprons. METHODS: The experimental setup involved 2 anthropomorphic phantoms, an operator, a patient, and a C-arm as the x-ray radiation source. Thermoluminescent detectors were used to measure radiation doses to different radiosensitive body parts on the operator phantom both with the exoskeleton and a conventional lead apron at the left radial and right femoral positions. Detected radiation doses for the exoskeleton and lead apron for different body parts and positions were compared. RESULTS: At the left radial position, the mean radiation dose (mGy) reduction by the exoskeleton compared with that by the lead apron was >90% for the left eye lens (0.22 ± 0.13 vs 5.18 ± 0.08; P 90% for the left eye lens (0.14 ± 0.10 vs 4.16 ± 0.09; P < .0001), right eye lens (0.06 ± 0.08 vs 1.90 ± 0.11; P < .0001), left head (0.10 ± 0.08 vs 4.39 ± 0.08; P < .0001), left brain (0.03 ± 0.07 vs 1.44 ± 0.08; P < .0001), right brain (0.00 ± 0.14 vs 0.11 ± 0.13; P = .06), and thyroid (0.04 ± 0.07 vs 0.27 ± 0.09; P < .0001). Protection of the torso was equivalent to that offered by conventional lead aprons. CONCLUSIONS: The exoskeleton-based system provided superior radiation protection to the physician compared with that provided by conventional lead aprons. The effects are particularly impactful for the brain, eye lens, and head areas.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionExoskeleton DeviceOccupational ExposureHumansRadiation DosageProtective ClothingHead

Autor:innen und Institutionen

  • Houston Methodist DeBakey Heart and Vascular Center, Houston Methodist Hospital, Houston, Texas; Section of Vascular Surgery, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca'Granda Ospedale Maggiore Po…
  • Department of Interventional Radiology (B.Z.), University of South Florida Morsani College of Medicine, Tampa, Florida.
  • StemRad Inc., Tampa, Florida.
  • Division of Vascular Surgery, Department of Surgery, University of South Florida Morsani College of Medicine, Tampa, Florida.
  • Institute of Aerospace Medicine, Radiation Biology Department, German Aerospace Center, Cologne, Germany.
  • Division of Vascular Surgery, Louisiana State University School of Medicine, New Orleans, Louisiana.

Zitieren

APA

Katsarou, M., Zwiebel, B., Chowdhury, R. P., Shames, M., Berger, T., Przybyla, B., & Bismuth, J. (2023). Experimental Analysis of Radiation Protection Offered by a Novel Exoskeleton-Based Radiation Protection System versus Conventional Lead Aprons. Journal of Vascular and Interventional Radiology. https://doi.org/10.1016/j.jvir.2023.03.033

Vancouver

Katsarou M, Zwiebel B, Chowdhury RP, Shames M, Berger T, Przybyla B, et al. Experimental Analysis of Radiation Protection Offered by a Novel Exoskeleton-Based Radiation Protection System versus Conventional Lead Aprons. Journal of Vascular and Interventional Radiology. 2023. doi:10.1016/j.jvir.2023.03.033

BibTeX
@article{Katsarou2023,
  author = {Katsarou, Maria and Zwiebel, Bruce and Chowdhury, Rajarshi Pal and Shames, Murray and Berger, Thomas and Przybyla, Bartos and Bismuth, Jean},
  title = {Experimental Analysis of Radiation Protection Offered by a Novel Exoskeleton-Based Radiation Protection System versus Conventional Lead Aprons},
  journal = {Journal of Vascular and Interventional Radiology},
  year = {2023},
  doi = {10.1016/j.jvir.2023.03.033}
}