Impact of X‐Ray Protective Drapes on Operator and Patient Radiation Exposure During Cardiac Catheterization
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31329 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Michel de Ceuninck und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, AZ Delta, Roeselare, Belgium. Hauptthemen laut MEDLINE: Radiation Protection, Cardiac Catheterization, Radiation Exposure, Radiation Dosage. Die Arbeit nennt 8 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
As cardiac catheterization operators are exposed to radiation exposure throughout their careers, optimal radiation protection is crucial. Our study was designed to assess the effects of supplementary protective measures beyond standard radiation protection attire and barriers, measuring their influence on scatter radiation exposure levels for both the operator and the patient.
Aims
The objective of this trial is to assess the impact of a lead shield on scatter radiation exposure for both the operator and the patient.
Methods
We conducted a prospective, randomized clinical trial in which procedures were allocated to incorporate the use of a reusable lead apron designed to shield the lower body of the patient. Both operators and patients were outfitted with real‐time procedure‐specific dosimeters to monitor exposure. All patients undergoing radial access procedures were entered into a randomization process. The study's dual primary outcomes included the relative operator dose above (RODt) and under (RODu) the protective gear, as well as the scatter patient radiation dose (RPD), which was calculated as the measured radiation exposure (µSv) standardized against the dose area product (DAP).
Results
Out of 400 procedures that were randomized, data from 346 procedures was complete for analysis. The use of the pelvic shield resulted in a substantial decrease in the RODt and RODu, with reductions of 25% and 40%, respectively ( p < 0.0001). There was also a 38% reduction observed in the scatter RPD. In patients with a high BMI, the effectiveness of the pelvic shield varied.
Conclusion
Employing an auxiliary pelvic shield significantly diminishes scatter radiation exposure for both the operator and the patient.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, AZ Delta, Roeselare, Belgium.
- Department of Cardiology, Sint-Andriesziekenhuis, Tielt, Belgium.
- Department of Cardiology, Sint Jozefskliniek Izegem, Izegem, Belgium.
- Department of IT and Data, AZ Delta, Roeselare, Belgium.
- Department of Prevention, AZ Delta, Roeselare, Belgium.
ORCID-Profile: Michel de Ceuninck
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
de Ceuninck, M., Dujardin, K., Vanhaverbeke, M., Muyldermans, P., de Walle, S. V., Pauwelyn, M., Bergez, B., Desimpel, F., Vanderheeren, P., Dekerpel, F., Kamoen, V., Beveren, J. V., Bruneel, W., Coillie, P. V., & Cokelaere, B. (2025). Impact of X‐Ray Protective Drapes on Operator and Patient Radiation Exposure During Cardiac Catheterization. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31329
Vancouver
de Ceuninck M, Dujardin K, Vanhaverbeke M, Muyldermans P, de Walle SV, Pauwelyn M, et al. Impact of X‐Ray Protective Drapes on Operator and Patient Radiation Exposure During Cardiac Catheterization. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31329
BibTeX
@article{deCeuninck2025,
author = {de Ceuninck, Michel and Dujardin, Karl and Vanhaverbeke, Maarten and Muyldermans, Philip and de Walle, Stefaan Van and Pauwelyn, Maarten and Bergez, Bernard and Desimpel, Francine and Vanderheeren, Philippe and Dekerpel, Filip and Kamoen, Victor and Beveren, Jan Van and Bruneel, Wim and Coillie, Patrick Van and Cokelaere, Benny},
title = {Impact of X‐Ray Protective Drapes on Operator and Patient Radiation Exposure During Cardiac Catheterization},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31329}
}
EUVIMED