Attempt to re-estimate organ doses of victims in non-homogeneous exposure accident by means of the state-of-the-art Mesh-type Reference Computational Phantom—a case study of an IR-192 source accident
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae070 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Munehiko Kowatari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Measurement and Dose Assessment, Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, …. Hauptthemen laut MEDLINE: Phantoms, Imaging, Monte Carlo Method, Radiation Dosage, Radioactive Hazard Release. Die Arbeit nennt 9 Literaturangaben.
Abstract (Originalsprache)
An attempt was made to estimate organ doses of a victim in a high-dose non-homogeneous exposure accident caused by a sealed 192Ir gamma-ray source. The Gilan accident was selected as a case study. Organ doses including testis, red bone marrow and so on were properly estimated by applying the Monte Carlo calculation with the state-of-the-art adult male Mesh type Reference Computational Phantom. By introducing a complicated exposure scenario, the dose distribution on the right chest of the victim in the Gilan accident could be reproduced to a certain extent.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiation Measurement and Dose Assessment, Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, Anagawa 4-9-1, Inage, Chiba 263-8555, Japan.
- Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, Shirakata 2-4, Tokai, Ibaraki 319-1195, Japan.
Zitieren
APA
Kowatari, M., Yoshitomi, H., Tani, K., Tanimura, Y., & Kurihara, O. (2024). Attempt to re-estimate organ doses of victims in non-homogeneous exposure accident by means of the state-of-the-art Mesh-type Reference Computational Phantom—a case study of an IR-192 source accident. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae070
Vancouver
Kowatari M, Yoshitomi H, Tani K, Tanimura Y, Kurihara O. Attempt to re-estimate organ doses of victims in non-homogeneous exposure accident by means of the state-of-the-art Mesh-type Reference Computational Phantom—a case study of an IR-192 source accident. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae070
BibTeX
@article{Kowatari2024,
author = {Kowatari, Munehiko and Yoshitomi, Hiroshi and Tani, Kotaro and Tanimura, Yoshihiko and Kurihara, Osamu},
title = {Attempt to re-estimate organ doses of victims in non-homogeneous exposure accident by means of the state-of-the-art Mesh-type Reference Computational Phantom—a case study of an IR-192 source accident},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae070}
}
EUVIMED