Dosimetric comparison of O-ring versus conventional C-arm linear accelerator for volumetric modulated arc therapy (VMAT) of head and neck cancer and carcinoma cervix patients
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae043 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Vibhor Patodi und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Bhagwan Mahaveer Cancer Hospital and Research Centre, Jaipur, Rajasthan, India. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Uterine Cervical Neoplasms, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
The objective of this study is dosimetric comparison between the O-ring Halcyon and C-arm Clinac iX linac for volumetric modulated arc therapy (VMAT) plans for head & neck (H&N) cancer and carcinoma cervix patients. Total 60 patients of H&N cancer and carcinoma cervix were enrolled prospectively from March 2021 to March 2023. VMAT plans with 6 MV photons for Halcyon and Clinac iX were generated and compared for each patient by dose volume histogram for planning target volume coverage and organ at risk (OAR) sparing. There were no differences in between both the linacs for PTV D2% and D98%, homogeneity index, conformity index, Dmax (maximum dose) and Dmean (mean dose) of OAR. Halcyon had significantly shorter treatment time compared to Clinac iX. Halcyon delivered higher integral dose and monitor units. O-ring Halcyon produces VMAT plans comparable to other C-arm linacs for H&N and carcinoma cervix patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiation Oncology, Bhagwan Mahaveer Cancer Hospital and Research Centre, Jaipur, Rajasthan, India.
- Department of Surgical Oncology, Bhagwan Mahaveer Cancer Hospital and Research Centre, Jaipur, Rajasthan, India.
- Department of Medical Oncology, Bhagwan Mahaveer Cancer Hospital and Research Centre, Jaipur, Rajasthan, India.
- Department of Clinical Trials, Bhagwan Mahaveer Cancer Hospital and Research Centre, Jaipur, Rajasthan, India.
- Department of Radiation Oncology, Narayana Multispeciality Hospital, Jaipur, Rajasthan, India.
ORCID-Profile: Tej P Soni
Zitieren
APA
Patodi, V., Soni, T. P., Singh, D. K., Patni, N., Jakhotia, N., Chittappurath, V., Kuyyanangadan, R., Jenny, A., Kanniyappan, E., Gupta, A. K., Gupta, T. C., Singhal, H., Natrajan, T., & Kather, F. S. (2024). Dosimetric comparison of O-ring versus conventional C-arm linear accelerator for volumetric modulated arc therapy (VMAT) of head and neck cancer and carcinoma cervix patients. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae043
Vancouver
Patodi V, Soni TP, Singh DK, Patni N, Jakhotia N, Chittappurath V, et al. Dosimetric comparison of O-ring versus conventional C-arm linear accelerator for volumetric modulated arc therapy (VMAT) of head and neck cancer and carcinoma cervix patients. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae043
BibTeX
@article{Patodi2024,
author = {Patodi, Vibhor and Soni, Tej P and Singh, Dinesh K and Patni, Nidhi and Jakhotia, Naresh and Chittappurath, Vineeth and Kuyyanangadan, Rajkamal and Jenny, Ashna and Kanniyappan, Elumalai and Gupta, Anil K and Gupta, Tara C and Singhal, Harish and Natrajan, Thirumoorthy and Kather, Farzana S},
title = {Dosimetric comparison of O-ring versus conventional C-arm linear accelerator for volumetric modulated arc therapy (VMAT) of head and neck cancer and carcinoma cervix patients},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae043}
}
EUVIMED