Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Hui Xiao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Peking University Third Hospital, Beijing, P. R. China. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Radiotherapy, Intensity-Modulated, Cone-Beam Computed Tomography, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program, Bethune Charitable Foundation, Special Fund of National Clinical Key Specialty Construction Program of China (2021).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aims to analyze setup errors in pelvic Volumetric Modulated Arc Therapy (VMAT) for patients with non‐surgical primary cervical cancer, utilizing the onboard iterative kV cone beam CT (iCBCT) imaging system on the Varian Halcyon 2.0 ring gantry structure accelerator to enhance radiotherapy precision.

Method

We selected 132 cervical cancer patients who underwent VMAT with daily iCBCT imaging guidance. Before each treatment session, a registration method based on the bony structure was employed to acquire iCBCT images with the corresponding planning CT images. Following verification and adjustment of image registration results along the three axes (but not rotational), setup errors in the lateral (X‐axis), longitudinal (Y‐axis), and vertical (Z‐axis) directions were recorded for each patient. Subsequently, we analyzed 3642 iCBCT image setup errors.

Results

The mean setup errors for the X, Y, and Z axes were 4.50 ± 3.79 mm, 6.08 ± 6.30 mm, and 1.48 ± 2.23 mm, respectively. Before correction with iCBCT, setup margins based on the Van Herk formula for the X, Y, and Z axes were 6.28, 12.52, and 3.26 mm, respectively. In individuals aged 60 years and older, setup errors in the X and Y axes were significantly larger than those in the younger group ( p < 0.05). Additionally, there is no significant linear correlation between setup errors and treatment fraction numbers.

Conclusion

Data analysis underscores the importance of precise Y‐axis setup for cervical cancer patients undergoing VMAT. Radiotherapy centers without daily iCBCT should appropriately extend the planning target volume (PTV) along the Y‐axis for cervical cancer patients receiving pelvic VMAT. Elderly patients exhibit significantly larger setup errors compared to younger counterparts. In conclusion, iCBCT‐guided radiotherapy is recommended for cervical cancer patients undergoing VMAT to improve setup precision.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Uterine Cervical NeoplasmsRadiotherapy, Intensity-ModulatedCone-Beam Computed TomographyRadiotherapy Planning, Computer-AssistedRadiotherapy DosageRadiotherapy Setup ErrorsHumansFemaleMiddle AgedAgedAdultImage Processing, Computer-AssistedRadiotherapy, Image-GuidedAged, 80 and overOrgans at RiskParticle AcceleratorsPrognosis

Stichwörter der Autor:innen

cervical canceriterative kV cone beam CT (iCBCT)setup errorsvolumetric modulated arc therapy (VMAT)

Autor:innen und Institutionen

  • Department of Radiation Oncology, Peking University Third Hospital, Beijing, P. R. China.

ORCID-Profile: Hui Xiao

Förderung

  • National Key Research and Development Program
  • Bethune Charitable Foundation
  • Special Fund of National Clinical Key Specialty Construction Program of China (2021)
  • Key Specialty program of Natural Science Foundation of Beijing Municipality
  • National Key Research and Development Program of China

Zitieren

APA

Xiao, H., Han, Q., Wei, S., Du, M., Deng, X., Zhang, N., Li, C., Wang, J., Qu, A., & Jiang, P. (2024). Setup errors analysis in iterative kV CBCT: A clinical study of cervical cancer treated with Volumetric Modulated Arc Therapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14480

Vancouver

Xiao H, Han Q, Wei S, Du M, Deng X, Zhang N, et al. Setup errors analysis in iterative kV CBCT: A clinical study of cervical cancer treated with Volumetric Modulated Arc Therapy. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14480

BibTeX
@article{Xiao2024,
  author = {Xiao, Hui and Han, Qiman and Wei, Shuhua and Du, Minghao and Deng, Xiuwen and Zhang, Nan and Li, Chunxiao and Wang, Junjie and Qu, Ang and Jiang, Ping},
  title = {Setup errors analysis in iterative kV CBCT: A clinical study of cervical cancer treated with Volumetric Modulated Arc Therapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14480}
}
Kostenlos starten →