Neutron spectrum measurements near KAMINI reactor south beam vault door using nested neutron spectrometer
Radiation Protection Dosimetry · 17.07.2024 · 200 (11-12) · 1132-1137
DOI: 10.1093/rpd/ncae015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 17.07.2024. Verfasst von D Venkata Subramanian und 4 weiteren Autor:innen. Beteiligte Einrichtung: Reactor Shielding and Data Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, India. Hauptthemen laut MEDLINE: Neutrons, Nuclear Reactors, Gamma Rays, Radiation Dosage. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 5 Literaturangaben.
Abstract (Originalsprache)
KAlpakkam MINI reactor (KAMINI) is a 233U fuelled research reactor has various neutron irradiation locations for experimental purposes. The pit at the south beam end of KAMINI reactor is being extensively utilised for neutron attenuation experiments in prospective shielding materials as well as for neutron radiography. During reactor operation, it will be closed by a movable shield. A vault door is located above the shield and the movable shield is used to attenuate streaming neutrons and gamma-rays during reactor operation. Even with the shield, there exists significant dose because of streaming neutrons and gamma rays. Its variation depends on the power of the reactor. The neutron and gamma dose rates close to the south beam vault door have recently been found to be 275–300 μSv/h and 175–200 μSv/h, respectively, when the reactor is operating at 10 kW. In order to characterise the streaming neutron spectra of vault door place for the first time, measurements are done using the Nested Neutron Spectrometer. Along with the neutron flux, neutron mean energy and ambient dose-equivalent rate are also measured and compared with earlier measurements carried out inside the south beam pit. It is observed that the presence of paraffin shield reduces the neutron average energy from 370 to 178 keV. Apart from energy reduction, 10 kW normalised neutron flux of south beam pit is also attenuated by the shield by 25 000 times and it is found that the neutron spectrum of the measured location is also more thermalized. Neutron reference data of the location are generated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Reactor Shielding and Data Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, India.
Zitieren
APA
Subramanian, D. V., Haridas, A., Kumar, D. S., Pandikumar, G., & Arul, A. J. (2024). Neutron spectrum measurements near KAMINI reactor south beam vault door using nested neutron spectrometer. Radiation Protection Dosimetry, 200(11-12), 1132-1137. https://doi.org/10.1093/rpd/ncae015
Vancouver
Subramanian DV, Haridas A, Kumar DS, Pandikumar G, Arul AJ. Neutron spectrum measurements near KAMINI reactor south beam vault door using nested neutron spectrometer. Radiation Protection Dosimetry. 2024;200(11-12):1132-1137. doi:10.1093/rpd/ncae015
BibTeX
@article{Subramanian2024,
author = {Subramanian, D Venkata and Haridas, Adish and Kumar, D Sunil and Pandikumar, G and Arul, A John},
title = {Neutron spectrum measurements near KAMINI reactor south beam vault door using nested neutron spectrometer},
journal = {Radiation Protection Dosimetry},
year = {2024},
volume = {200},
number = {11-12},
pages = {1132--1137},
doi = {10.1093/rpd/ncae015}
}
EUVIMED