EUVIMEDEUVIMED entdecken
Crossref

Multisignal ionization chamber with a B4C coating as an active neutron beam spectrometer: Monte Carlo simulations

Maciej Maciak iD, Szymon Domański, Piotr Tulik, Katarzyna Tymińska, Michał Aleksander Gryziński iD

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncac291 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Maciej Maciak und 4 weiteren Autor:innen. Beteiligte Einrichtung: Warsaw University of Technology, Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, św. Andrzeja Boboli 8, Warsaw 02-525, Po…. Hauptthemen laut MEDLINE: Radiometry, Neutrons. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, the influence of additional 10B4C polarizing electrodes coating on KW-1 multisignal ionization chamber performance was investigated. Using the FLUKA Monte Carlo code energy deposition, neutron fluence and neutron track-length distributions were simulated. Further calculations allow us to obtain response functions for monoenergetic neutron beams in the energy range from 1 meV to 30 MeV. Results indicate further upgrades that can be adapted for moderator-based gaseous detectors for the neutron beam spectrometry approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiometryNeutronsComputer SimulationMonte Carlo MethodGases

Substanzen

Gases

Autor:innen und Institutionen

  • Warsaw University of Technology, Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, św. Andrzeja Boboli 8, Warsaw 02-525, Poland.
  • National Centre for Nuclear Research, Nuclear Facilities Operations Department, Radiological Metrology and Biomedical Physics Division, Andrzeja Sołtana 7, Otwock 05-400, Poland.

ORCID-Profile: Maciej Maciak, Michał Aleksander Gryziński

Zitieren

APA

Maciak, M., Domański, S., Tulik, P., Tymińska, K., & Gryziński, M. A. (2023). Multisignal ionization chamber with a B4C coating as an active neutron beam spectrometer: Monte Carlo simulations. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac291

Vancouver

Maciak M, Domański S, Tulik P, Tymińska K, Gryziński MA. Multisignal ionization chamber with a B4C coating as an active neutron beam spectrometer: Monte Carlo simulations. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac291

BibTeX
@article{Maciak2023,
  author = {Maciak, Maciej and Domański, Szymon and Tulik, Piotr and Tymińska, Katarzyna and Gryziński, Michał Aleksander},
  title = {Multisignal ionization chamber with a B4C coating as an active neutron beam spectrometer: Monte Carlo simulations},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncac291}
}
Kostenlos starten →