A comprehensive Monte Carlo simulation of the neutron response of multi-element microdosimetric detectors based on THick Gas Electron Multiplier
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncad013 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von R Singh und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4L8, Canada. Hauptthemen laut MEDLINE: Radiometry, Electrons. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 7 Literaturangaben. Gefördert von: CANDU Owners Group, Canada and Natural Sciences and Engineering Research Council.
Abstract (Originalsprache)
We present comprehensive Monte Carlo simulations for the neutron response of the multi-element microdosimetric detector based on THick Gas Electron Multiplier (THGEM). Simulations were carried out using the MCNP6.2 code to calculate the deposited energy spectrum in the gaseous sensitive volumes for three different configurations, 7 × 3, 19 × 5, 37 × 7 that occupy a cylindrical volume of 5-cm diameter by 5-cm length. The energy response was computed from 10 keV to 2 MeV. The response variation was investigated between sensitive volumes as well as between layers. The simulated energy response showed a good agreement against the evaluated fluence-to-kerma conversion coefficients in the energy region 10–100 keV, whereas discrepancies were observed in the region above 250 keV. The angular response simulations showed a variation of less than 10%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4L8, Canada.
Förderung
- CANDU Owners Group
- Canada and Natural Sciences and Engineering Research Council
Zitieren
APA
Singh, R., & Byun, S. H. (2023). A comprehensive Monte Carlo simulation of the neutron response of multi-element microdosimetric detectors based on THick Gas Electron Multiplier. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad013
Vancouver
Singh R, Byun SH. A comprehensive Monte Carlo simulation of the neutron response of multi-element microdosimetric detectors based on THick Gas Electron Multiplier. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad013
BibTeX
@article{Singh2023,
author = {Singh, R and Byun, S H},
title = {A comprehensive Monte Carlo simulation of the neutron response of multi-element microdosimetric detectors based on THick Gas Electron Multiplier},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncad013}
}