Fachartikel in der Zeitschrift European Radiology, 2023. Verfasst von Damiano Caruso und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical-Surgical Sciences and Translational Medicine, Radiology Unit, Sant'Andrea University Hospital, Sapienza University of Rome, Via…. Hauptthemen laut MEDLINE: Deep Learning, Liver Neoplasms. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Roma La Sapienza.
Abstract (Originalsprache)
Objectives
To perform a comprehensive within-subject image quality analysis of abdominal CT examinations reconstructed with DLIR and to evaluate diagnostic accuracy compared to the routinely applied adaptive statistical iterative reconstruction (ASiR-V) algorithm. Materials and methods Oncologic patients were prospectively enrolled and underwent contrast-enhanced CT. Images were reconstructed with DLIR with three intensity levels of reconstruction (high, medium, and low) and ASiR-V at strength levels from 10 to 100% with a 10% interval. Three radiologists characterized the lesions and two readers assessed diagnostic accuracy and calculated signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), figure of merit (FOM), and subjective image quality, the latter with a 5-point Likert scale.
Results
Fifty patients (mean age: 70 ± 10 years, 23 men) were enrolled and 130 liver lesions (105 benign lesions, 25 metastases) were identified. DLIR_H achieved the highest SNR and CNR, comparable to ASiR-V 100% ( p ≥ .051). DLIR_M returned the highest subjective image quality (score: 5; IQR: 4–5; p ≤ .001) and significant median increase (29%) in FOM ( p < .001). Differences in detection were identified only for lesions ≤ 0.5 cm: 32/33 lesions were detected with DLIR_M and 26 lesions were detected with ASiR-V 50% ( p = .031). Lesion accuracy of was 93.8% (95% CI: 88.1, 97.3; 122 of 130 lesions) for DLIR and 87.7% (95% CI: 80.8, 92.8; 114 of 130 lesions) for ASiR-V 50%.
Conclusions
DLIR yields superior image quality and provides higher diagnostic accuracy compared to ASiR-V in the assessment of hypovascular liver lesions, in particular for lesions ≤ 0.5 cm. Clinical relevance statement Deep learning image reconstruction algorithm demonstrates higher diagnostic accuracy compared to iterative reconstruction in the identification of hypovascular liver lesions, especially for lesions ≤ 0.5 cm. Key Points • Iterative reconstruction algorithm impacts image texture, with negative effects on diagnostic capabilities. • Medium-strength deep learning image reconstruction algorithm outperforms iterative reconstruction in the diagnostic accuracy of ≤ 0.5 cm hypovascular liver lesions (93.9% vs 78.8%), also granting higher objective and subjective image quality. • Deep learning image reconstruction algorithm can be safely implemented in routine abdominal CT protocols in place of iterative reconstruction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical-Surgical Sciences and Translational Medicine, Radiology Unit, Sant'Andrea University Hospital, Sapienza University of Rome, Via Di Grottarossa, 1035-1039, 00189, Rome, Italy.
- Department of Medical-Surgical Sciences and Translational Medicine, Radiology Unit, Sant'Andrea University Hospital, Sapienza University of Rome, Via Di Grottarossa, 1035-1039, 00189, Rome, Italy. andrea.laghi@uniroma1.…
Förderung
- Università degli Studi di Roma La Sapienza
Zitieren
APA
Caruso, D., De Santis, D., Del Gaudio, A., Guido, G., Zerunian, M., Polici, M., Valanzuolo, D., Pugliese, D., Persechino, R., Cremona, A., Barbato, L., Caloisi, A., Iannicelli, E., & Laghi, A. (2023). Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm. European Radiology. https://doi.org/10.1007/s00330-023-10171-8
Vancouver
Caruso D, De Santis D, Del Gaudio A, Guido G, Zerunian M, Polici M, et al. Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm. European Radiology. 2023. doi:10.1007/s00330-023-10171-8
BibTeX
@article{Caruso2023,
author = {Caruso, Damiano and De Santis, Domenico and Del Gaudio, Antonella and Guido, Gisella and Zerunian, Marta and Polici, Michela and Valanzuolo, Daniela and Pugliese, Dominga and Persechino, Raffaello and Cremona, Antonio and Barbato, Luca and Caloisi, Andrea and Iannicelli, Elsa and Laghi, Andrea},
title = {Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm},
journal = {European Radiology},
year = {2023},
doi = {10.1007/s00330-023-10171-8}
}
EUVIMED