EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Estimating Blood Volume Loss With Wireless, Wearable Ultrasound: A Pilot Investigation

Jon-Emile S Kenny iD, Melissa Hebscher, Tracy Savery, Sarah Atwi, Daniel Lachner-Piza, Andrew M Eibl, Joseph K Eibl, Soumya Vungarala, Niki M Dietz, Chul-Ho Kim, Bruce D Johnson

Military Medicine · 01.08.2026 · 191 (Supplement_1) · 386-392

DOI: 10.1093/milmed/usag109 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Military Medicine, online erschienen am 06.08.2026. Verfasst von Jon-Emile S Kenny und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Research, Health Sciences North Research Institute Walford Site, Greater Sudbury, ON P3E 2H9, Canada. Hauptthemen laut MEDLINE: Blood Volume, Wearable Electronic Devices. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Office of the Assistant Secretary of Defense for Health Affairs, Congressionally Directed Medical Research Program, Department of Defense.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Detecting and estimating blood volume loss are important for the diagnosis and management of life-threatening hemorrhage. There is a direct relationship between percent blood volume loss (BVL%) and falling in stroke volume (SV); furthermore, there is a direct relationship between diminishing SV and the corrected flow time of the carotid artery (ccFT). Therefore, we hypothesized that change in ccFT (ccFTΔ) would directly relate with BVL% in a phlebotomy paradigm. Materials and Methods A prospective, convenience sample of healthy volunteers was studied. Volunteers underwent blood donation protocol in a physiology lab. A wireless, wearable Doppler ultrasound system monitored ccFT during blood donation. Traditional vital signs were also measured throughout. The relationship between traditional vital signs as well as ccFTΔ were compared to BVL% using 2 mixed linear regression models.

Results

Data from 20 subjects and blood donations comprising 46,123 cardiac cycles are included. On average 413.5 ± 39 mL of blood were drawn representing 8.6 ± 1.6% BVL%. There was a significant and strong linear relationship between BVL% and ccFTΔ during blood draw with the regression slope demonstrating that for every 1 ms reduction in ccFT there was a 0.4% reduction in blood volume.

Conclusions

In healthy subjects and when blood loss is the sole mechanism for falling SV, we estimate that for every 1 ms reduction in ccFT, there is an approximate 0.4 BVL%. Validation of these results in patients with traumatic hemorrhage is underway.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood VolumeWearable Electronic DevicesHumansPilot ProjectsMaleAdultFemaleProspective StudiesUltrasonographyMiddle AgedBlood DonationWireless Technology

Autor:innen und Institutionen

  • Department of Clinical Research, Health Sciences North Research Institute Walford Site, Greater Sudbury, ON P3E 2H9, Canada.
  • Department of Engineering, Flosonics Medical, Toronto, ON M5V 2Y1, Canada.
  • Department of Engineering, Flosonics Medical, Greater Sudbury, ON P3E 2H9, Canada.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, United States.
  • Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN 55905, United States.
  • Human Integrative and Environmental Physiology Laboratory, Mayo Clinic, Rochester, MN 55905, United States.

ORCID-Profile: Jon-Emile S Kenny

Förderung

  • Office of the Assistant Secretary of Defense for Health Affairs
  • Congressionally Directed Medical Research Program
  • Department of Defense

Zitieren

APA

Kenny, J. S., Hebscher, M., Savery, T., Atwi, S., Lachner-Piza, D., Eibl, A. M., Eibl, J. K., Vungarala, S., Dietz, N. M., Kim, C. H., & Johnson, B. D. (2026). Estimating Blood Volume Loss With Wireless, Wearable Ultrasound: A Pilot Investigation. Military Medicine, 191(Supplement_1), 386-392. https://doi.org/10.1093/milmed/usag109

Vancouver

Kenny JS, Hebscher M, Savery T, Atwi S, Lachner-Piza D, Eibl AM, et al. Estimating Blood Volume Loss With Wireless, Wearable Ultrasound: A Pilot Investigation. Military Medicine. 2026;191(Supplement_1):386-392. doi:10.1093/milmed/usag109

BibTeX
@article{Kenny2026,
  author = {Kenny, Jon-Emile S and Hebscher, Melissa and Savery, Tracy and Atwi, Sarah and Lachner-Piza, Daniel and Eibl, Andrew M and Eibl, Joseph K and Vungarala, Soumya and Dietz, Niki M and Kim, Chul-Ho and Johnson, Bruce D},
  title = {Estimating Blood Volume Loss With Wireless, Wearable Ultrasound: A Pilot Investigation},
  journal = {Military Medicine},
  year = {2026},
  volume = {191},
  number = {Supplement_1},
  pages = {386--392},
  doi = {10.1093/milmed/usag109}
}
Kostenlos starten →