EUVIMEDEUVIMED entdecken
VergleichsstudieMultizentrische Studie

Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study

Xue Lu iD, Jia Liu iD, Jinxiu Ju iD, Weiran Long iD, Zeping Huang iD, Jie Ren iD

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025

DOI: 10.1002/rcs.70099 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Xue Lu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China. Hauptthemen laut MEDLINE: Ultrasonography, Robotics, Teleradiology, Image Processing, Computer-Assisted. Die Arbeit nennt 27 Literaturangaben. Gefördert von: Guangdong Medical Science and Technology Research Foundation, The Municipal Schools Joint Funding Project Basic Research Programme encompasses the Municipal Key Laboratory Construction Project, High-tech and major technology projects in Guangzhou.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to assess the ability of a 5G‐based telerobotic system to generate required images of diagnostic quality in multi‐organ US examinations. Materials and Methods This prospective study involved participants in Shenzhen and Tibet, which are 106 and 4000 km, respectively, from the tele‐radiologist's hospital. Participants underwent telerobotic US examinations from September 2020 to March 2021. A total of 127 participants were enrolled. The required image quality was evaluated by the required image adequacy, image quality, the observer reliability and the consistency of the conventional US. The safety assessments were assessed by complications and questionnaires.

Results

A total of 1790/2032 (88.1%) required images were considered adequate, and 167/2032 (8.2%) were considered adequate with some reservations. The mean image quality score was 2.83 ± 0.47 on a three‐point Likert scale and did not differ between the districts or sexes. Telerobotic US detected 15 out of 18 abnormalities (83.3%) in 10 patients who underwent both telerobotic US and conventional US. There was good consistency between the two methods ( k = 0.7–1.0). Furthermore, nearly 86.0% of patients accepted and would be willing to undergo another telerobotic US examination in the future. Teleradiologists accepted almost all US examinations as adequate for diagnosis and were satisfied with them.

Conclusions

The 5G‐based telerobotic US(MGIUS‐R3) can acquire required images with adequacy and quality in multiple organ examination procedures, with high safety and customer satisfaction in this limited group of patients. Further studies with larger samples and more centres are needed to validate this potential new technology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UltrasonographyRoboticsTeleradiologyImage Processing, Computer-AssistedQuality of Health CareProspective StudiesPilot ProjectsAbdomenPelvisThyroid GlandPoint-of-Care TestingReproducibility of ResultsLiverHumansMaleFemaleAdolescentYoung AdultAdultMiddle AgedAgedChinaPatient Acceptance of Health Care

Stichwörter der Autor:innen

5G‐powered telerobotic ultrasound systemmulti‐organquality and safety assessments

Autor:innen und Institutionen

  • Department of Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
  • Chaya People's Hospital, Changdu, China.

ORCID-Profile: Xue Lu, Jia Liu, Jinxiu Ju, Weiran Long, Zeping Huang, Jie Ren

Förderung

  • Guangdong Medical Science and Technology Research Foundation
  • The Municipal Schools Joint Funding Project Basic Research Programme encompasses the Municipal Key Laboratory Construction Project
  • High-tech and major technology projects in Guangzhou
  • The Rural and Social Development Science and Technology Major Programme in Guangzhou
  • Fifth Five-Year Project of the Third Affiliated Hospital of Sun Yat-Sen University
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • National Natural Science Foundation of China

Zitieren

APA

Lu, X., Liu, J., Ju, J., Long, W., Huang, Z., & Ren, J. (2025). Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70099

Vancouver

Lu X, Liu J, Ju J, Long W, Huang Z, Ren J. Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70099

BibTeX
@article{Lu2025,
  author = {Lu, Xue and Liu, Jia and Ju, Jinxiu and Long, Weiran and Huang, Zeping and Ren, Jie},
  title = {Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70099}
}
Kostenlos starten →