EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance of Continuous Digital Monitoring of Vital Signs with a Wearable Sensor in Acute Hospital Settings

Meera Joshi iD, Fahad M Iqbal iD, Mansour Sharabiani iD, Hutan Ashrafian, Sonal Arora, Kenny McAndrew, Sadia Khan iD, Graham Cooke, Ara Darzi

Sensors · 22.04.2025 · 25 (9) · 2644

DOI: 10.3390/s25092644 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 22.04.2025. Verfasst von Meera Joshi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery and Cancer, Imperial College London, London W2 1NY, UK. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Vital Signs. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute for Health Research (NIHR) Imperial Biomedical Research Centre (BRC), National Institute for Health Research (NIHR) Imperial Patient Safety Translational Research Centre, Royal College of Surgeons England Research Fellowship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Continuous vital sign monitoring using wearable sensors has gained traction for the early detection of patient deterioration, particularly with the advent of virtual wards.

Objective

The objective was to evaluate the reliability of a wearable sensor for monitoring heart rate (HR), respiratory rate (RR), and temperature in acutely unwell hospital patients and to identify the optimal time window for alert generation.

Methods

A prospective cohort study recruited 500 patients in a single hospital. Sensor readings were compared to standard intermittent nurse observations using Bland–Altman plots to assess the limits of agreement.

Results

HR demonstrated good agreement with nurse observations (intraclass correlation coefficient [ICC] = 0.66, r = 0.86, p < 0.001), with a mean difference of 3.63 bpm (95% LoA: −10.87 to 18.14 bpm). RR exhibited weaker agreement (ICC = 0.20, r = 0.18, p < 0.001), with a mean difference of −2.72 breaths per minute (95% LoA: −10.91 to 5.47 bpm). Temperature showed poor to fair agreement (ICC = 0.30, r = 0.39, p < 0.001), with a mean difference of −0.57 °C (95% LoA: −1.72 to 0.58 °C). A 10 min averaging window was identified as optimal, balancing data retention and real-time alerting.

Conclusions

Wearable sensors demonstrate potential for reliable continuous monitoring of vital signs, supporting their future integration into real-world clinical practice for improved patient safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesVital SignsHumansMonitoring, PhysiologicMaleFemaleHeart RateRespiratory RateMiddle AgedAgedProspective StudiesHospitalsAdultBody TemperatureReproducibility of Results

Stichwörter der Autor:innen

continuous monitoringvital signswearable sensors

Autor:innen und Institutionen

  • Department of Surgery and Cancer, Imperial College London, London W2 1NY, UK.
  • Department of Primary Care & Public Health, School of Public Health, Imperial College London, London W6 8RP, UK.
  • Chelsea and Westminster Hospital, NHS Foundation Trust, London SW10 9NH, UK.
  • Division of Infectious Diseases, Imperial College London, London W2 1NY, UK.

ORCID-Profile: Meera Joshi, Fahad M Iqbal, Mansour Sharabiani, Sadia Khan

Förderung

  • National Institute for Health Research (NIHR) Imperial Biomedical Research Centre (BRC)
  • National Institute for Health Research (NIHR) Imperial Patient Safety Translational Research Centre
  • Royal College of Surgeons England Research Fellowship
  • CW plus charity
  • NIHR Professorship

Zitieren

APA

Joshi, M., Iqbal, F. M., Sharabiani, M., Ashrafian, H., Arora, S., McAndrew, K., Khan, S., Cooke, G., & Darzi, A. (2025). Performance of Continuous Digital Monitoring of Vital Signs with a Wearable Sensor in Acute Hospital Settings. Sensors, 25(9), 2644. https://doi.org/10.3390/s25092644

Vancouver

Joshi M, Iqbal FM, Sharabiani M, Ashrafian H, Arora S, McAndrew K, et al. Performance of Continuous Digital Monitoring of Vital Signs with a Wearable Sensor in Acute Hospital Settings. Sensors. 2025;25(9):2644. doi:10.3390/s25092644

BibTeX
@article{Joshi2025,
  author = {Joshi, Meera and Iqbal, Fahad M and Sharabiani, Mansour and Ashrafian, Hutan and Arora, Sonal and McAndrew, Kenny and Khan, Sadia and Cooke, Graham and Darzi, Ara},
  title = {Performance of Continuous Digital Monitoring of Vital Signs with a Wearable Sensor in Acute Hospital Settings},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {9},
  pages = {2644},
  doi = {10.3390/s25092644}
}
Kostenlos starten →