Establishing multianalyte thresholds for automated detection of EDTA contamination

Jillian Kodger, Thomas J S Durant iD, Dustin Miconi, Joe M El-Khoury iD

Laboratory Medicine · 10.06.2026 · 57 (4)

DOI: 10.1093/labmed/lmag041 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laboratory Medicine, online erschienen am 17.07.2026. Verfasst von Jillian Kodger und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Yale School of Medicine, New Haven, CT, United States. Hauptthemen laut MEDLINE: Edetic Acid, Automation, Laboratory, Blood Chemical Analysis. Die Arbeit nennt 6 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Bias in analytes due to EDTA contamination is easy to miss and represents a common and clinically relevant preanalytical error. We designed a study to determine the in vitro effects of rising rates of EDTA contamination in blood samples and to evaluate how these findings could inform the development of multianalyte thresholds for detecting such errors automatically.

Methods

We incrementally spiked blood samples with increasing volumes of EDTA‑contaminated specimen and measured the resulting changes in alkaline phosphatase, calcium, magnesium, potassium, and iron levels. Using these observations, we developed a series of multianalyte thresholds and evaluated their performance against 1 year of retrospective clinical data (n = 2407).

Results

Our experiments demonstrated that increasing rates of EDTA contamination produced changes in several analytes. Accordingly, we applied multianalyte thresholds using potassium and calcium to retrospective samples. Across all samples, smaller magnitudes of analyte deviation resulted in higher detection rates of subtle EDTA contamination but poorer specificity. We selected a rule of a potassium level of 6.5 mmol/L or higher and a calcium level below 6.5 mg/dL (1.63 mmol/L), which identified 14 samples with a contamination rate of 42.8%.

Discussion

Multianalyte thresholds show promise as an effective approach for automatically identifying clinically significant EDTA contamination in clinical specimens.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Edetic AcidAutomation, LaboratoryBlood Chemical AnalysisHumansRetrospective Studies

Stichwörter der Autor:innen

EDTAautomated detectionmultianalyte checkpreanalytical

Substanzen

Edetic Acid

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Yale School of Medicine, New Haven, CT, United States.

ORCID-Profile: Thomas J S Durant, Joe M El-Khoury

Zitieren

APA

Kodger, J., Durant, T. J. S., Miconi, D., & El-Khoury, J. M. (2026). Establishing multianalyte thresholds for automated detection of EDTA contamination. Laboratory Medicine, 57(4). https://doi.org/10.1093/labmed/lmag041

Vancouver

Kodger J, Durant TJS, Miconi D, El-Khoury JM. Establishing multianalyte thresholds for automated detection of EDTA contamination. Laboratory Medicine. 2026;57(4). doi:10.1093/labmed/lmag041

BibTeX
@article{Kodger2026,
  author = {Kodger, Jillian and Durant, Thomas J S and Miconi, Dustin and El-Khoury, Joe M},
  title = {Establishing multianalyte thresholds for automated detection of EDTA contamination},
  journal = {Laboratory Medicine},
  year = {2026},
  volume = {57},
  number = {4},
  doi = {10.1093/labmed/lmag041}
}
Kostenlos starten →