Haemodynamic Performance of Transcatheter Heart Valve in Bileaflet Mechanical Valve: An In-vitro Study
Interdisciplinary CardioVascular and Thoracic Surgery · 2025
DOI: 10.1093/icvts/ivaf265 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Chiara Catalano und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering, Viale delle Scienze, Università degli Studi di Palermo, Palermo, 90128, Italy. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Hemodynamics, Transcatheter Aortic Valve Replacement, Aortic Valve. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: European Commission-Next Generation, European Commission—Next Generation.
Abstract (Originalsprache)
Objectives
This study evaluates the haemodynamic performance of a novel hybrid configuration—Valve-in-MHV—where a CoreValve transcatheter heart valve is implanted within the annulus of a composite valved graft after leaflet removal.
Methods
In vitro testing was performed using left heart mock loop combined with backlight particle image velocimetry. Three configurations were assessed: (i) mechanical heart valve (MHV), (ii) CoreValve THV, and (iii) Valve-in-MHV. Flow parameters were measured at cardiac outputs of 3 and 5 L/min.
Results
At 5 L/min, the Valve-in-MHV showed the highest PG (15.5 mmHg) and TKE (0.53 m2/s2), compared to the THV (10.9 mmHg, 0.31 m2/s2) and MHV (11.5 mmHg, 0.26 m2/s2). Effective orifice area was smallest for the Valve-in-MHV (1.44 cm2). The Valve-in-MHV generated a more physiological central jet than the MHV, but with increased turbulence and higher peak velocities (up to 2.66 m/s).
Conclusions
Examining the mechanistic implications of Valve-in-MHV may offer valuable insights into the likelihood of adverse effects such as leaflet thrombosis and the development of pronounced pressure gradients in patients who are candidates for Valve-in-MHV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering, Viale delle Scienze, Università degli Studi di Palermo, Palermo, 90128, Italy.
- Department of Research, IRCCS ISMETT via Tricomi, Palermo, 90127, Italy.
- Department of Cardiac Surgery, Inselspital, Bern University Hospital, and University of Bern, Bern, 3010, Switzerland.
- Department of Cardiology, Inselspital, Bern University Hospital, and University of Bern, Bern, 3010, Switzerland.
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, 3008, Switzerland.
ORCID-Profile: Chiara Catalano, Salvatore Pasta, Eric Buffle, Matthias Siepe, Dominik Obrist
Förderung
- European Commission-Next Generation
- European Commission—Next Generation
Zitieren
APA
Catalano, C., Pasta, S., Potratz, P., Buffle, E., Siepe, M., & Obrist, D. (2025). Haemodynamic Performance of Transcatheter Heart Valve in Bileaflet Mechanical Valve: An In-vitro Study. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf265
Vancouver
Catalano C, Pasta S, Potratz P, Buffle E, Siepe M, Obrist D. Haemodynamic Performance of Transcatheter Heart Valve in Bileaflet Mechanical Valve: An In-vitro Study. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf265
BibTeX
@article{Catalano2025,
author = {Catalano, Chiara and Pasta, Salvatore and Potratz, Paul and Buffle, Eric and Siepe, Matthias and Obrist, Dominik},
title = {Haemodynamic Performance of Transcatheter Heart Valve in Bileaflet Mechanical Valve: An In-vitro Study},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2025},
doi = {10.1093/icvts/ivaf265}
}
EUVIMED