Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Kimihiro Kobayashi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Second Department of Surgery, Faculty of Medicine, Yamagata University, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan. Hauptthemen laut MEDLINE: Heart Valve Prosthesis Implantation, Coronary Vessels, Heart Valve Prosthesis, Aortic Valve. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The valve-in-valve procedure is an alternative to the redo surgery for structural valve deterioration following the Bio-Bentall. However, the risk of coronary obstruction and the feasibility of this approach remain unclear. Using computed tomography, we compared the aortic root geometry of 14 consecutive patients (13 true aortic aneurysms) with Bio-Bentall between April 2011 and April 2024 preoperatively and postoperatively. The Piehler technique was used in all coronary artery reconstructions. During the follow-up period, no reconstructive coronary events or valve-related reoperations were observed. The coronary height was 17.7 ± 5.6 mm preoperatively versus 18.8 ± 4.4 mm postoperatively for the left coronary artery (P = 0.49) and 15.4 ± 9.6 mm preoperatively versus 22.6 ± 7.4 mm postoperatively for the right coronary artery (P < 0.01). No patients at risk of coronary obstruction associated with valve-in-valve were identified. One case of severe aortic graft kinking due to excessive graft length, which could contraindicate the valve-in-valve procedure, was observed. Our findings suggested that the Piehler technique may facilitate future valve-in-valve implantation after Bio-Bentall because it allows for a higher-positioned orifice of the reconstructive coronary artery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve Prosthesis ImplantationCoronary VesselsHeart Valve ProsthesisAortic ValveAortic AneurysmBlood Vessel Prosthesis ImplantationBioprosthesisHumansMaleFemaleAgedMiddle AgedTreatment OutcomeRetrospective StudiesComputed Tomography AngiographyProsthesis DesignCoronary Angiography

Stichwörter der Autor:innen

Bio-Bentallaortic root geometrycoronary heightvalve-in-valve

Autor:innen und Institutionen

  • Second Department of Surgery, Faculty of Medicine, Yamagata University, 2-2-2 Iidanishi, Yamagata, 990-9585, Japan.

ORCID-Profile: Kimihiro Kobayashi, Yoshinori Kuroda, Masahiro Mizumoto, Jun Hayashi, Tetsuro Uchida

Zitieren

APA

Kobayashi, K., Kuroda, Y., Mizumoto, M., Hayashi, J., Hirooka, S., Akabane, K., Ochiai, T., & Uchida, T. (2025). Evaluation of coronary heights after Bio-Bentall using Piehler technique. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf150

Vancouver

Kobayashi K, Kuroda Y, Mizumoto M, Hayashi J, Hirooka S, Akabane K, et al. Evaluation of coronary heights after Bio-Bentall using Piehler technique. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf150

BibTeX
@article{Kobayashi2025,
  author = {Kobayashi, Kimihiro and Kuroda, Yoshinori and Mizumoto, Masahiro and Hayashi, Jun and Hirooka, Shuto and Akabane, Kentaro and Ochiai, Tomonori and Uchida, Tetsuro},
  title = {Evaluation of coronary heights after Bio-Bentall using Piehler technique},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2025},
  doi = {10.1093/icvts/ivaf150}
}
Kostenlos starten →