Mechanical versus bioprosthetic valve for aortic valve replacement in dialysis patients: Systematic review and individual patient data meta-analysis
Asian Cardiovascular and Thoracic Annals · 2024
DOI: 10.1177/02184923241301108 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Asian Cardiovascular and Thoracic Annals, 2024. Verfasst von Ioannis Zoupas und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cardiothoracic and Vascular Surgery Working Group, Society of Junior Doctors, Athens, Greece. Hauptthemen laut MEDLINE: Bioprosthesis, Heart Valve Prosthesis, Aortic Valve, Heart Valve Prosthesis Implantation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Objective
There is little evidence regarding the most beneficial choice between a mechanical and a bioprosthetic valve in the aortic position in dialysis patients. This meta-analysis compares the survival and freedom from reintervention rates between mechanical and bioprosthetic valves in patients on dialysis undergoing aortic valve replacement surgery.
Methods
Two databases were searched, and the systematic review was performed in accordance with the recommendations of the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. We conducted one-stage and two-stage meta-analysis with Kaplan–Meier-derived individual patient data and meta-analysis with random-effects model.
Results
Eight studies were included, providing data about 1215 dialysis patients receiving mechanical valves and 1851 patients receiving bioprosthetic valves. During a mean follow-up of 43.1 months, overall survival rates were significantly improved in the mechanical valve group in comparison to the bioprosthetic one (hazard ratio [HR]: 0.76, 95% confidence interval [CI]: 0.69–0.84, p < 0.001). This was confirmed by the two-stage meta-analysis (HR: 0.72, 95% CI: 0.62–0.83, p = 0.00, I 2 = 17.79%). Regarding freedom from reintervention, no arm offered a statistically significant advantage, according to the two-stage generated analysis (HR: 1.025, 95% CI: 0.65–1.61, p = 0.914). Similarly, there was no evident superiority of a valve type for perioperative outcomes.
Conclusions
Mechanical valves are likely to be associated with a better survival outcome compared to bioprosthetic valves for patients on dialysis undergoing aortic valve replacement. However, freedom from reoperation rates and perioperative outcomes were comparable between the two valve types, with no arm exhibiting a statistically significant advantage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiothoracic and Vascular Surgery Working Group, Society of Junior Doctors, Athens, Greece.
- Department of Cardiac Surgery, Hygeia Hospital, Athens, Greece.
- Department of Cardiothoracic Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
- Department of Vascular Surgery, AHEPA University Hospital, Thessaloniki, Greece.
- Department of Cardiac Surgery, Faculty of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
- Department of Cardiac Surgery, Imperial College London, London, UK.
ORCID-Profile: Ioannis Zoupas, Iosif Namidis
Zitieren
APA
Zoupas, I., Loufopoulos, G., Tasoudis, P. T., Manaki, V., Namidis, I., Caranasos, T. G., Iliopoulos, D. C., & Athanasiou, T. (2024). Mechanical versus bioprosthetic valve for aortic valve replacement in dialysis patients: Systematic review and individual patient data meta-analysis. Asian Cardiovascular and Thoracic Annals. https://doi.org/10.1177/02184923241301108
Vancouver
Zoupas I, Loufopoulos G, Tasoudis PT, Manaki V, Namidis I, Caranasos TG, et al. Mechanical versus bioprosthetic valve for aortic valve replacement in dialysis patients: Systematic review and individual patient data meta-analysis. Asian Cardiovascular and Thoracic Annals. 2024. doi:10.1177/02184923241301108
BibTeX
@article{Zoupas2024,
author = {Zoupas, Ioannis and Loufopoulos, Georgios and Tasoudis, Panagiotis T and Manaki, Vasiliki and Namidis, Iosif and Caranasos, Thomas G and Iliopoulos, Dimitrios C and Athanasiou, Thanos},
title = {Mechanical versus bioprosthetic valve for aortic valve replacement in dialysis patients: Systematic review and individual patient data meta-analysis},
journal = {Asian Cardiovascular and Thoracic Annals},
year = {2024},
doi = {10.1177/02184923241301108}
}
EUVIMED