Comprehensive assessment of aortic flow before and after aortic valve replacement in an ex vivo porcine model with four-dimensional flow magnetic resonance imaging
Interdisciplinary CardioVascular and Thoracic Surgery · 2025
DOI: 10.1093/icvts/ivaf087 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Hiroyuki Saisho und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany. Hauptthemen laut MEDLINE: Aortic Valve, Heart Valve Prosthesis Implantation, Aorta, Magnetic Resonance Imaging. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Stiftung für Herzforschung.
Abstract (Originalsprache)
OBJECTIVES Aortic valve replacement (AVR) has shown to induce secondary flow patterns deviating from main flow. It is impossible to analyse the impact of surgical access and different AVR techniques under standardized conditions in patients or silicone models. Therefore, we developed an ex vivo swine model to analyse the impact of surgical access and to compare flow patterns after different AVR techniques within the ascending aorta. METHODS Porcine aortas (n = 6) were anastomosed to a custom-made piston pump. The pulse duplicator perfused the aortas with a blood-mimicking fluid at 2.5 l/min and 64 bpm. 4D flow magnetic resonance imaging of each aorta was acquired prior to surgery (NAV, n = 6), after sham surgery (aortotomy and closure thereof without valve replacement, NAV-A, n = 6) and after Ozaki procedure (AVneo, n = 2), biological valve (BV, n = 2) or mechanical valve (MV, n = 2). Secondary flow patterns and peak velocity were analysed with GTFlow (GyroTools, Switzerland). RESULTS Sham surgery alone induced secondary flow patterns in the ascending aorta in all specimens. After AVR, more secondary flow patterns were observed distal to BV compared to AVneo or MV. Three flow patterns developed after BV, two after AVneo and one after MV. In addition, peak velocity within the aortic sinuses of Valsalva increased after all AVR procedures, most strikingly after BV (NAV = 75 ± 22 cm/s, NAV-A = 79 ± 29 cm/s, AVneo = 115 ± 36 cm/s, BV = 142 ± 21 cm/s, MV = 107 ± 4 cm/s; mean±standard deviation). CONCLUSIONS We successfully established an ex vivo model suggesting that flow alterations not only depend on the type of AVR but are associated with surgical access. The strongest secondary flow patterns developed after BV followed by AVneo and MV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany.
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany.
- Section of Pediatric Radiology, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Department of Radiology, University of Wisconsin, Madison, WI, USA.
ORCID-Profile: Michael Scharfschwerdt, Stephan Ensminger, Alex Frydrychowicz
Förderung
- Deutsche Stiftung für Herzforschung
Zitieren
APA
Saisho, H., Balks, M. F., Scharfschwerdt, M., Schaller, T., Sadat, N., Aboud, A., Ensminger, S., Frydrychowicz, A., Fujita, B., & Oechtering, T. H. (2025). Comprehensive assessment of aortic flow before and after aortic valve replacement in an ex vivo porcine model with four-dimensional flow magnetic resonance imaging. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf087
Vancouver
Saisho H, Balks MF, Scharfschwerdt M, Schaller T, Sadat N, Aboud A, et al. Comprehensive assessment of aortic flow before and after aortic valve replacement in an ex vivo porcine model with four-dimensional flow magnetic resonance imaging. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf087
BibTeX
@article{Saisho2025,
author = {Saisho, Hiroyuki and Balks, Maren Friederike and Scharfschwerdt, Michael and Schaller, Tim and Sadat, Najla and Aboud, Anas and Ensminger, Stephan and Frydrychowicz, Alex and Fujita, Buntaro and Oechtering, Thekla Helene},
title = {Comprehensive assessment of aortic flow before and after aortic valve replacement in an ex vivo porcine model with four-dimensional flow magnetic resonance imaging},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2025},
doi = {10.1093/icvts/ivaf087}
}
EUVIMED