EUVIMEDEUVIMED entdecken
Crossref

Long-term results of a stented bioprosthetic valve in the aortic position: structural valve deterioration and valve haemodynamic deterioration of bovine pericardial and porcine valves

Yoo Jin Jung iD, Jae Woong Choi iD, Yoonjin Kang, Ji Seong Kim, Suk Ho Sohn, Ho Young Hwang iD, Kyung Hwan Kim

European Journal of Cardio-Thoracic Surgery · 2023

DOI: 10.1093/ejcts/ezac506 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2023. Verfasst von Yoo Jin Jung und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic…. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Bioprosthesis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES This study compared the clinical outcomes of bovine and porcine bioprosthetic valves based on structural valve deterioration (SVD) and valve haemodynamic deterioration (VHD) in the aortic position. METHODS From January 1995 to December 2014, patients who underwent aortic valve replacement (AVR) using a bovine pericardial valve or porcine valve were enrolled. SVD and VHD were defined according to the mean transprosthetic gradient and the grade of aortic regurgitation on transthoracic echocardiography. The propensity score matching was used to adjust for differences in preoperative and operative characteristics. RESULTS A total of 520 patients were enrolled. Of these, 372 patients underwent AVR using a bovine pericardial valve and 148 patients underwent AVR using a porcine valve. Then, 135 pairs of patients were extracted after propensity score matching. The median follow-up duration was 8.2 years (interquartile range, 5.4–11.3). Among the matched patients, no significant differences occurred in overall survival (survival at 10 years: 64.7% vs 70.9%) or cardiac death (cumulative incidence at 10 years: 14.2% vs 13.1%) between the 2 groups. The cumulative incidence of moderate or greater SVD and VHD was significantly higher in the porcine valve group than in the bovine valve group (SVD at 10 years—porcine: 29.8% vs bovine: 13%; VHD at 10 years—porcine: 19.8% vs bovine: 3.8%, respectively). However, no significant differences were noted in the cumulative incidence of severe SVD and severe VHD between the 2 groups. CONCLUSIONS The bovine pericardial valve should be considered in AVR because the cumulative incidences of moderate or greater SVD and VHD were significantly lower than those of the porcine valve.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisHeart Valve Prosthesis ImplantationBioprosthesisAnimalsCattleSwineProsthesis FailureAortic ValveHemodynamicsProsthesis DesignTreatment Outcome

Stichwörter der Autor:innen

stented bioprosthetic valvestructural valve deteriorationvalve hemodynamic deterioration

Autor:innen und Institutionen

  • Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.

ORCID-Profile: Yoo Jin Jung, Jae Woong Choi, Ho Young Hwang

Zitieren

APA

Jung, Y. J., Choi, J. W., Kang, Y., Kim, J. S., Sohn, S. H., Hwang, H. Y., & Kim, K. H. (2023). Long-term results of a stented bioprosthetic valve in the aortic position: structural valve deterioration and valve haemodynamic deterioration of bovine pericardial and porcine valves. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezac506

Vancouver

Jung YJ, Choi JW, Kang Y, Kim JS, Sohn SH, Hwang HY, et al. Long-term results of a stented bioprosthetic valve in the aortic position: structural valve deterioration and valve haemodynamic deterioration of bovine pericardial and porcine valves. European Journal of Cardio-Thoracic Surgery. 2023. doi:10.1093/ejcts/ezac506

BibTeX
@article{Jung2023,
  author = {Jung, Yoo Jin and Choi, Jae Woong and Kang, Yoonjin and Kim, Ji Seong and Sohn, Suk Ho and Hwang, Ho Young and Kim, Kyung Hwan},
  title = {Long-term results of a stented bioprosthetic valve in the aortic position: structural valve deterioration and valve haemodynamic deterioration of bovine pericardial and porcine valves},
  journal = {European Journal of Cardio-Thoracic Surgery},
  year = {2023},
  doi = {10.1093/ejcts/ezac506}
}
Kostenlos starten →