EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modes of failure of Trifecta aortic valve prosthesis

Pietro Giorgio Malvindi iD, Hassan Kattach, Suvitesh Luthra, Sunil Ohri iD

Interactive CardioVascular and Thoracic Surgery · 09.07.2022 · 35 (2)

DOI: 10.1093/icvts/ivac086 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Interactive CardioVascular and Thoracic Surgery, online erschienen am 28.03.2022. Verfasst von Pietro Giorgio Malvindi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Wessex Cardiothoracic Centre, Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Bioprosthesis, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES Several concerns have been recently raised regarding the durability of Trifecta prostheses. Different mechanisms of early failure were reported. Our aim was to study in a large population the modes of failure of Trifecta valves. METHODS We conducted a retrospective analysis of patients who underwent surgical aortic valve replacement with a Trifecta prosthesis during the period 2010–2018. Details regarding the mode of failure and haemodynamic dysfunction were collected for patients who underwent reintervention for structural valve failure. The Kaplan–Meier method was used to calculate survival. Competing risk analysis was performed to calculate the cumulative risk of reintervention for structural valve failure. RESULTS The overall population comprises 1228 patients (1084 TF model and 144 TFGT model). Forty-four patients—mean patients’ age at the time of the first implant 69 (standard deviation: 12) years and 61% female—underwent reintervention for structural valve failure after a median time of 63 [44–74] months. The cumulative incidence of reintervention for structural valve failure was 0.16% (SE 0.11%), 1.77% (SE 0.38%) and 5.11% (SE 0.98%) at 1, 5 and 9 years, respectively. In 24/44 patients (55%), a leaflet tear with dehiscence at the commissure level was found intraoperatively or described by imaging assessment. The cumulative incidence of reintervention for failure due to leaflet(s) tear was 0.16% (SE 0.11%), 1.08% (SE 0.29%) and 3.03% (SE 0.88%) at 1, 5 and 9 years, respectively. CONCLUSIONS Leaflet(s) tear with dehiscence along the stent post was the main mode of early failure, up to 5 years, after Trifecta valves’ implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisBioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationAortic ValveFemaleHemodynamicsHumansMaleProsthesis DesignProsthesis FailureRetrospective Studies

Stichwörter der Autor:innen

Aortic valveAortic valve prosthesisAortic valve replacement

Autor:innen und Institutionen

  • Wessex Cardiothoracic Centre, Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK.
  • University of Southampton, Southampton, UK.

ORCID-Profile: Pietro Giorgio Malvindi, Sunil Ohri

Zitieren

APA

Malvindi, P. G., Kattach, H., Luthra, S., & Ohri, S. (2022). Modes of failure of Trifecta aortic valve prosthesis. Interactive CardioVascular and Thoracic Surgery, 35(2). https://doi.org/10.1093/icvts/ivac086

Vancouver

Malvindi PG, Kattach H, Luthra S, Ohri S. Modes of failure of Trifecta aortic valve prosthesis. Interactive CardioVascular and Thoracic Surgery. 2022;35(2). doi:10.1093/icvts/ivac086

BibTeX
@article{Malvindi2022,
  author = {Malvindi, Pietro Giorgio and Kattach, Hassan and Luthra, Suvitesh and Ohri, Sunil},
  title = {Modes of failure of Trifecta aortic valve prosthesis},
  journal = {Interactive CardioVascular and Thoracic Surgery},
  year = {2022},
  volume = {35},
  number = {2},
  doi = {10.1093/icvts/ivac086}
}
Kostenlos starten →